Determination of narrow beam attenuation coefficients from a broad beam geometrical configuration for 320 keV photons

H.A. Jahagirdar, B. Hanumaiah, S.R. Thontadarya
{"title":"Determination of narrow beam attenuation coefficients from a broad beam geometrical configuration for 320 keV photons","authors":"H.A. Jahagirdar,&nbsp;B. Hanumaiah,&nbsp;S.R. Thontadarya","doi":"10.1016/0883-2889(92)90180-M","DOIUrl":null,"url":null,"abstract":"<div><p>Narrow beam mass attenuation coefficients, μ/ρ, of 320 keV photons, emitted from the <sup>51</sup>Cr radioisotope have been measured in various high <em>Z</em> materials such as Pb; BiPO<sub>4</sub>; (CH<sub>3</sub>COO)<sub>2</sub>·Pb·3H<sub>2</sub>O; Pb(NO<sub>3</sub>)<sub>2</sub>; Na<sub>2</sub>WO<sub>4</sub>·2H<sub>2</sub>O, using a broad beam geometrical configuration, employing a 2′' × 1′' (5.1 <em>cm</em> × 2.54 <em>cm</em>) (0.051 <em>m</em> × 0.025 <em>m</em>) NaI (Tl) detector spectrometer system coupled to a 1 k multichannel analyser. The measured μ/ρ values in cm<sup>2</sup>/g for the above materials in the transmission range from 50% to 20% respectively are 0.34 ± 0.01 (0.35); 0.295 ± 0.002 (0.30); 0.23 ± 0.01 (0.24); 0.256 ± 0.003 (0.26); 0.255 ± 0.003 (0.256). The values given in parentheses are estimated theoretically from the mixture rule using tabulated values of Hubbell (1982). It is observed that for high <em>Z</em> compounds at low energies, the exponential law of attenuation will be valid even for a broad beam set up in the transmission range from 50% to 20%. The attenuation coefficients of elements derived from this method agree fairly well with the tabulated narrow beam attenuation coefficients indicating the validity of the mixture rule in this region of transmission.</p></div>","PeriodicalId":14288,"journal":{"name":"International Journal of Radiation Applications and Instrumentation. Part A. Applied Radiation and Isotopes","volume":"43 12","pages":"Pages 1511-1514"},"PeriodicalIF":0.0000,"publicationDate":"1992-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0883-2889(92)90180-M","citationCount":"21","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Radiation Applications and Instrumentation. Part A. Applied Radiation and Isotopes","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/088328899290180M","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 21

Abstract

Narrow beam mass attenuation coefficients, μ/ρ, of 320 keV photons, emitted from the 51Cr radioisotope have been measured in various high Z materials such as Pb; BiPO4; (CH3COO)2·Pb·3H2O; Pb(NO3)2; Na2WO4·2H2O, using a broad beam geometrical configuration, employing a 2′' × 1′' (5.1 cm × 2.54 cm) (0.051 m × 0.025 m) NaI (Tl) detector spectrometer system coupled to a 1 k multichannel analyser. The measured μ/ρ values in cm2/g for the above materials in the transmission range from 50% to 20% respectively are 0.34 ± 0.01 (0.35); 0.295 ± 0.002 (0.30); 0.23 ± 0.01 (0.24); 0.256 ± 0.003 (0.26); 0.255 ± 0.003 (0.256). The values given in parentheses are estimated theoretically from the mixture rule using tabulated values of Hubbell (1982). It is observed that for high Z compounds at low energies, the exponential law of attenuation will be valid even for a broad beam set up in the transmission range from 50% to 20%. The attenuation coefficients of elements derived from this method agree fairly well with the tabulated narrow beam attenuation coefficients indicating the validity of the mixture rule in this region of transmission.

320 keV光子宽光束几何结构窄光束衰减系数的测定
在各种高Z物质(如Pb)中测量了51Cr放射性同位素发射的320 keV光子的窄束质量衰减系数μ/ρ;BiPO4;(CH3COO) 2·3 Pb·h2o;Pb(3号)2;Na2WO4·2H2O,采用宽光束几何结构,采用2“× 1”(5.1 cm × 2.54 cm) (0.051 m × 0.025 m) NaI (Tl)探测器光谱仪系统与1 k多通道分析仪耦合。上述材料在50% ~ 20%透射率范围内测得μ/ρ值(cm2/g)分别为0.34±0.01 (0.35);0.295±0.002 (0.30);0.23±0.01 (0.24);0.256±0.003 (0.26);0.255±0.003(0.256)。括号内给出的值是使用Hubbell(1982)的表列值从混合规则理论上估计的。我们观察到,对于低能量的高Z化合物,即使在50% ~ 20%的传输范围内设置宽光束,衰减的指数定律仍然有效。该方法得到的单元衰减系数与表列的窄波束衰减系数吻合较好,表明混合规则在该传输区域的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信