Comparison of Chloride-Induced Corrosion of Microsilica and ECC in the Offshore Piers' Concrete (Case Study: Wharves P3 & P4 of Imam Khomeini Petrochemical)

A. Tangtakabi, M. H. Ramesht, A. G. Pahlaviani
{"title":"Comparison of Chloride-Induced Corrosion of Microsilica and ECC in the Offshore Piers' Concrete (Case Study: Wharves P3 & P4 of Imam Khomeini Petrochemical)","authors":"A. Tangtakabi, M. H. Ramesht, A. G. Pahlaviani","doi":"10.11648/j.eas.20210604.11","DOIUrl":null,"url":null,"abstract":"The corrosion of reinforcements in the tidal zone leads to significant damage to offshore concrete piers. To overcome such damages, the quality of concrete and its mechanical properties should be improved. The aim of the present study is to identify and evaluate the causes and extent of corrosion observed in piers P3 & P4 in Imam Khomeini petrochemical. The concrete reinforced by microsilica and the ECC concrete are used to prevent corrosion. Some tests were conducted to determine the conditions of concrete piers in terms of reinforcement corrosion. Then, a reinforcement corrosion intensity test using Potentiostat involving a placement process was used, where the water-to-cement ratio was 38%; superplasticizers was 4%; and microsilica was 10% and 15%. The microsilica can serve as an alternative to the consumed cement and was measured according to the ASTM standards; Besides, it was exposed to aggressive conditions at different periods, and a concrete compressive strength test was performed. The results show that the compressive strength of concrete with microsilica 15% is nearly 25% higher than that of ECC, while for the control specimen, this value is about 42%. Regarding the corrosion intensity, the concrete with microsilica 15% has the minimum value compare to all three other samples. It is recommended to use this type of concrete to overcome the corrosion problem in piers P3 & P4 in Imam Khomeini petrochemical.","PeriodicalId":15681,"journal":{"name":"Journal of Engineering and Applied Sciences","volume":"13 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-08-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Engineering and Applied Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11648/j.eas.20210604.11","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The corrosion of reinforcements in the tidal zone leads to significant damage to offshore concrete piers. To overcome such damages, the quality of concrete and its mechanical properties should be improved. The aim of the present study is to identify and evaluate the causes and extent of corrosion observed in piers P3 & P4 in Imam Khomeini petrochemical. The concrete reinforced by microsilica and the ECC concrete are used to prevent corrosion. Some tests were conducted to determine the conditions of concrete piers in terms of reinforcement corrosion. Then, a reinforcement corrosion intensity test using Potentiostat involving a placement process was used, where the water-to-cement ratio was 38%; superplasticizers was 4%; and microsilica was 10% and 15%. The microsilica can serve as an alternative to the consumed cement and was measured according to the ASTM standards; Besides, it was exposed to aggressive conditions at different periods, and a concrete compressive strength test was performed. The results show that the compressive strength of concrete with microsilica 15% is nearly 25% higher than that of ECC, while for the control specimen, this value is about 42%. Regarding the corrosion intensity, the concrete with microsilica 15% has the minimum value compare to all three other samples. It is recommended to use this type of concrete to overcome the corrosion problem in piers P3 & P4 in Imam Khomeini petrochemical.
海洋码头混凝土中微二氧化硅与ECC氯化物腐蚀的比较(以伊玛目霍梅尼石化P3、P4码头为例)
潮区钢筋锈蚀对近海混凝土桥墩的破坏十分严重。为了克服这种破坏,必须提高混凝土的质量和力学性能。本研究的目的是识别和评估在伊玛目霍梅尼石化公司P3和P4码头观察到的腐蚀原因和程度。采用微二氧化硅增强混凝土和ECC混凝土进行防腐蚀。进行了一些试验,以确定混凝土墩在钢筋腐蚀方面的条件。然后,使用电位器进行钢筋腐蚀强度测试,其中水灰比为38%;高效减水剂为4%;微二氧化硅为10%和15%。微二氧化硅可以作为消耗水泥的替代品,并根据ASTM标准进行测量;并对其进行了不同时期的侵蚀试验,进行了混凝土抗压强度试验。结果表明:掺微二氧化硅15%的混凝土抗压强度比ECC高近25%,而对照试件的抗压强度约为42%;在腐蚀强度方面,掺量为微二氧化硅15%的混凝土与其他三种样品相比具有最小值。伊玛目霍梅尼石化P3、P4桥墩腐蚀问题推荐使用该类型混凝土。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信