A Piezoelectric Sensor Concept for Measuring Piston Wetting in DISI Engines

A. Camacho, M. Hall
{"title":"A Piezoelectric Sensor Concept for Measuring Piston Wetting in DISI Engines","authors":"A. Camacho, M. Hall","doi":"10.4271/2005-01-3873","DOIUrl":null,"url":null,"abstract":"A piezoelectric sensor to measure the mass of fuel that impacts the piston top during injection in a direct injection spark ignition (DISI) engine was developed. The sensor used a 3.18 cm (1.25-inch) long, 0.318 cm (0.125-inch) wide piezo bending motor. The principle of operation is based on the change in natural vibration frequency that occurs to the cantilever piezo beam due to a change in its mass caused by the presence of liquid fuel on its surface. An electrical impulse is used to set the piezo element in vibration after which the natural vibrational frequency is measured using a FFT analyzer. The concept was evaluated outside the engine and calibrated for the frequency shift as a function of the weight of liquid on the bending element. The change in the frequency was found to be approximately proportional to the liquid mass on the sensor. The piston top of the engine was modified to accommodate the sensor on its surface. Due to temperature limitations, all fuel film mass measurements were taken under motored conditions. A wide range of equivalence ratios and injection timings were considered in the experiments. The measurements showed that the fuel film mass deposited on the sensor surface was small, typically less than 2 mg, which corresponds to a film height of 32 μm. The fuel film mass followed a general trend increasing in value and reaching a maximum for injection timings when the piston surface approached TDC. The maximum measured mass for stoichiometric operation was 2.3 mg at TDC and corresponds to 6.3% of the fuel injected. The average evaporation rate of the fuel film mass was 3.3 kg/m 2 -s, and was nearly the same for all injection timings. The average measurement uncertainty was calculated as ±0.56 mg for stoichiometric operation.","PeriodicalId":21404,"journal":{"name":"SAE transactions","volume":"96 1","pages":"1756-1769"},"PeriodicalIF":0.0000,"publicationDate":"2005-10-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"SAE transactions","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4271/2005-01-3873","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

A piezoelectric sensor to measure the mass of fuel that impacts the piston top during injection in a direct injection spark ignition (DISI) engine was developed. The sensor used a 3.18 cm (1.25-inch) long, 0.318 cm (0.125-inch) wide piezo bending motor. The principle of operation is based on the change in natural vibration frequency that occurs to the cantilever piezo beam due to a change in its mass caused by the presence of liquid fuel on its surface. An electrical impulse is used to set the piezo element in vibration after which the natural vibrational frequency is measured using a FFT analyzer. The concept was evaluated outside the engine and calibrated for the frequency shift as a function of the weight of liquid on the bending element. The change in the frequency was found to be approximately proportional to the liquid mass on the sensor. The piston top of the engine was modified to accommodate the sensor on its surface. Due to temperature limitations, all fuel film mass measurements were taken under motored conditions. A wide range of equivalence ratios and injection timings were considered in the experiments. The measurements showed that the fuel film mass deposited on the sensor surface was small, typically less than 2 mg, which corresponds to a film height of 32 μm. The fuel film mass followed a general trend increasing in value and reaching a maximum for injection timings when the piston surface approached TDC. The maximum measured mass for stoichiometric operation was 2.3 mg at TDC and corresponds to 6.3% of the fuel injected. The average evaporation rate of the fuel film mass was 3.3 kg/m 2 -s, and was nearly the same for all injection timings. The average measurement uncertainty was calculated as ±0.56 mg for stoichiometric operation.
基于压电传感器的活塞湿润度测量
研制了一种压电传感器,用于测量直喷式火花点火(DISI)发动机喷射过程中撞击活塞顶部的燃油质量。该传感器使用了一个3.18厘米(1.25英寸)长,0.318厘米(0.125英寸)宽的压电弯曲电机。其工作原理是基于悬臂压电梁由于其表面存在液体燃料而引起的质量变化而发生的固有振动频率的变化。用电脉冲使压电元件处于振动状态,然后用FFT分析仪测量其固有振动频率。该概念在发动机外进行了评估,并校准了频率漂移作为弯曲元件上液体重量的函数。发现频率的变化与传感器上的液体质量近似成正比。发动机的活塞顶部经过修改,以适应其表面的传感器。由于温度的限制,所有的燃料膜质量测量都是在机动条件下进行的。实验中考虑了大范围的等效比和注射时间。测量结果表明,在传感器表面沉积的燃料膜质量很小,通常小于2 mg,对应的膜高度为32 μm。当活塞表面接近上止点时,燃油膜质量呈增加趋势,喷射正时达到最大值。化学计量操作的最大测量质量在上止点为2.3 mg,相当于注入燃料的6.3%。燃油膜质量的平均蒸发速率为3.3 kg/ m2 -s,并且在所有喷射时刻几乎相同。化学计量操作的平均测量不确定度为±0.56 mg。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信