{"title":"Positive Sequence Superimposed Based Islanding Detection Method Used in Distributed Generation","authors":"Javeed Bashir, P. Jena","doi":"10.13052/dgaej2156-3306.3821","DOIUrl":null,"url":null,"abstract":"This paper presents a passive method based localized islanding detection method for distributed generation (DG) connected to a main grid. The approach in this paper is based on the calculation of the magnitude of positive sequence based superimposed components of current and voltage, and the angle between them at the DG end. These three physical quantities altogether are used to identify the islanding. The prevailing active detection techniques introduce deliberately disturbances into the system which might lead to problems related to power quality, stability, and reliability of the power system. On the contrary, passive methods based islanding detection techniques has the issue of large non-detection zone (NDZ). The proposed technique overcomes the NDZ problem and does not introduce any disturbances. PSCAD/EMTDC is used to simulate the two systems. Various tests are carried out on these systems to access the execution of the proposed method and it was found that the suggested method has least NDZ and can detect the islanding within 10 ms well below the time required by a recloser which is 150 ms.","PeriodicalId":11205,"journal":{"name":"Distributed Generation & Alternative Energy Journal","volume":"90 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-01-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Distributed Generation & Alternative Energy Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.13052/dgaej2156-3306.3821","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This paper presents a passive method based localized islanding detection method for distributed generation (DG) connected to a main grid. The approach in this paper is based on the calculation of the magnitude of positive sequence based superimposed components of current and voltage, and the angle between them at the DG end. These three physical quantities altogether are used to identify the islanding. The prevailing active detection techniques introduce deliberately disturbances into the system which might lead to problems related to power quality, stability, and reliability of the power system. On the contrary, passive methods based islanding detection techniques has the issue of large non-detection zone (NDZ). The proposed technique overcomes the NDZ problem and does not introduce any disturbances. PSCAD/EMTDC is used to simulate the two systems. Various tests are carried out on these systems to access the execution of the proposed method and it was found that the suggested method has least NDZ and can detect the islanding within 10 ms well below the time required by a recloser which is 150 ms.
分布式发电中基于正序列叠加的孤岛检测方法
提出了一种基于被动方法的分布式发电并网局部孤岛检测方法。本文的方法是基于计算基于电流和电压叠加分量的正序幅值,以及它们在DG端之间的夹角。这三个物理量一起用来确定岛屿。现行的有源检测技术故意在系统中引入干扰,这可能导致与电力系统的质量、稳定性和可靠性有关的问题。相反,基于孤岛探测技术的被动方法存在较大的未探测区(NDZ)问题。所提出的技术克服了NDZ问题,并且不引入任何干扰。采用PSCAD/EMTDC对两种系统进行仿真。在这些系统上进行了各种测试,以访问所建议的方法的执行,发现所建议的方法具有最小的NDZ,并且可以在10 ms内检测到孤岛,远远低于重合闸所需的150 ms时间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信