Comparison of AC flashover performance for line post and pin post insulators in distribution 22 kV

W. Thipprasert, P. Jirapong
{"title":"Comparison of AC flashover performance for line post and pin post insulators in distribution 22 kV","authors":"W. Thipprasert, P. Jirapong","doi":"10.1109/ECTICON.2012.6254199","DOIUrl":null,"url":null,"abstract":"Electrical insulators of the Provincial Electricity Authority (PEA) of medium system are mostly porcelain insulator types that consists of suspension, pin type, line post, and pin post insulators. The distribution lines will be polluted by industrial contaminants, salt fog or natural dust. Experience shows that pollution flashover is one of the main natural calamities harming and affecting the voltage stability and reliability of distribution system. This paper compares the test results obtained from artificial pollution tests according to IEC 60507 with line post type and pin post type insulators of medium system under same test conditions. The salt fog test results indicate that the pollution flashover performance of line post insulator is less than to 50 percent of wet power frequency withstand voltage at equivalent salt deposit density (ESDD) = 0.5 mg/cm2 and the leakage current (LC) of line post insulator increased to 10.2 mA at ESDD = 0.5 mg/cm2 at nominal voltage. In the experiment indicate that AC pollution flashover performance of pin post insulator has better than line post insulator in the serious pollution area.","PeriodicalId":6319,"journal":{"name":"2012 9th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology","volume":"65 1","pages":"1-4"},"PeriodicalIF":0.0000,"publicationDate":"2012-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 9th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ECTICON.2012.6254199","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Electrical insulators of the Provincial Electricity Authority (PEA) of medium system are mostly porcelain insulator types that consists of suspension, pin type, line post, and pin post insulators. The distribution lines will be polluted by industrial contaminants, salt fog or natural dust. Experience shows that pollution flashover is one of the main natural calamities harming and affecting the voltage stability and reliability of distribution system. This paper compares the test results obtained from artificial pollution tests according to IEC 60507 with line post type and pin post type insulators of medium system under same test conditions. The salt fog test results indicate that the pollution flashover performance of line post insulator is less than to 50 percent of wet power frequency withstand voltage at equivalent salt deposit density (ESDD) = 0.5 mg/cm2 and the leakage current (LC) of line post insulator increased to 10.2 mA at ESDD = 0.5 mg/cm2 at nominal voltage. In the experiment indicate that AC pollution flashover performance of pin post insulator has better than line post insulator in the serious pollution area.
22 kV配电线柱绝缘子与针柱绝缘子交流闪络性能比较
省电力局中型系统的电绝缘子多为瓷绝缘子类型,包括悬挂式、针式、线柱式和针柱式绝缘子。配电线路会受到工业污染物、盐雾或自然粉尘的污染。经验表明,污染闪络是危害和影响配电系统电压稳定性和可靠性的主要自然灾害之一。本文将iec60507规定的人工污染试验结果与相同试验条件下介质系统的线柱式和针柱式绝缘子进行了比较。盐雾试验结果表明,当等效盐沉积密度(ESDD) = 0.5 mg/cm2时,线柱绝缘子的污闪性能小于湿工频耐压的50%;在标称电压下,当ESDD = 0.5 mg/cm2时,线柱绝缘子的漏电流(LC)增加到10.2 mA。实验表明,在污染严重的地区,针柱绝缘子的交流污闪性能优于线柱绝缘子。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信