THE INFLUENCE OF VEGETATION TO INDOOR ILLUMINANCE, AIR TEMPERATURE AND RELATIVE HUMIDITY IN DESIGN STUDIO (Case Study: Architecture Department, Petra Christian University, Surabaya)

W. Widigdo, S. Hartono, L. Kristanto, D. S. Mintorogo
{"title":"THE INFLUENCE OF VEGETATION TO INDOOR ILLUMINANCE, AIR TEMPERATURE AND RELATIVE HUMIDITY IN DESIGN STUDIO (Case Study: Architecture Department, Petra Christian University, Surabaya)","authors":"W. Widigdo, S. Hartono, L. Kristanto, D. S. Mintorogo","doi":"10.9744/dimensi.46.2.161-168","DOIUrl":null,"url":null,"abstract":"This research aimed to find the influence of vegetation outside the window to indoor light and thermal in Design studio, Architecture department of Petra Christian University, Surabaya. The vegetation was Shibataea kumasasa, cultivated in planter boxes, 90-100 centimeter high. The data was collected from the West and North window, for condition with and without vegetation outside the window. The measurement was taken on March until May 2019, using Hobo U12-012 data logger for measuring air temperature (°C), relative humidity (%) and illuminance (lux). Beside those physical measurement, the perception of 89 students as building user was also taken. The measurement result from windows facing West and North with the vegetation, the lowest indoor air temperature was 27°C with an average relative humidity of 70%. Meant it's at the upper edge of the comfort zoneof Bioclimatic Chart from Olgyay and Canada’s National Occupational Health & Safety Resource (CCOHS), so the indoor space was still uncomfortable and cooling was required to get into the comfort zone at warm humid climate. Result from lighting measurements obtained for west-oriented windows with vegetation outside the window, the highest illuminance was 350 lux at 02:45 pm, as well as for windows facing North at 07.30 am - 04.45 pm in range of 105 - 155 lux (highest). So, if there are vegetation outside windows, it will require electric lighting addition, because the illuminance are below the SNI 03-6197-2011which recommends 750 lux for design studio. Whilst the user respond from the questionnaire taken, stated that aesthetic vegetation was expected for natural element, blocked the penetration of solar radiation into indoor, and reduce glare to increase visual comfort without reducing luminous sufficiency for the visual activities in the design studio.","PeriodicalId":30518,"journal":{"name":"Dimensi Journal of Architecture and Built Environment","volume":"16 1","pages":"161-168"},"PeriodicalIF":0.0000,"publicationDate":"2020-02-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dimensi Journal of Architecture and Built Environment","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.9744/dimensi.46.2.161-168","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

This research aimed to find the influence of vegetation outside the window to indoor light and thermal in Design studio, Architecture department of Petra Christian University, Surabaya. The vegetation was Shibataea kumasasa, cultivated in planter boxes, 90-100 centimeter high. The data was collected from the West and North window, for condition with and without vegetation outside the window. The measurement was taken on March until May 2019, using Hobo U12-012 data logger for measuring air temperature (°C), relative humidity (%) and illuminance (lux). Beside those physical measurement, the perception of 89 students as building user was also taken. The measurement result from windows facing West and North with the vegetation, the lowest indoor air temperature was 27°C with an average relative humidity of 70%. Meant it's at the upper edge of the comfort zoneof Bioclimatic Chart from Olgyay and Canada’s National Occupational Health & Safety Resource (CCOHS), so the indoor space was still uncomfortable and cooling was required to get into the comfort zone at warm humid climate. Result from lighting measurements obtained for west-oriented windows with vegetation outside the window, the highest illuminance was 350 lux at 02:45 pm, as well as for windows facing North at 07.30 am - 04.45 pm in range of 105 - 155 lux (highest). So, if there are vegetation outside windows, it will require electric lighting addition, because the illuminance are below the SNI 03-6197-2011which recommends 750 lux for design studio. Whilst the user respond from the questionnaire taken, stated that aesthetic vegetation was expected for natural element, blocked the penetration of solar radiation into indoor, and reduce glare to increase visual comfort without reducing luminous sufficiency for the visual activities in the design studio.
植物对室内照度、空气温度和相对湿度的影响(以泗水佩特拉基督教大学建筑系为例)
本研究的目的是在泗水佩特拉基督教大学建筑系的设计工作室中发现窗外的植被对室内光和热的影响。植被为柴草(Shibataea kumasasa),种植在种植箱中,高90-100厘米。数据是从西窗和北窗收集的,包括窗外有和没有植被的情况。测量于2019年3月至5月进行,使用Hobo U12-012数据记录仪测量空气温度(°C),相对湿度(%)和照度(lux)。除了这些物理测量外,还测量了89名学生作为建筑物使用者的感知。在有植被的朝西和朝北窗户测量结果显示,室内最低气温为27℃,平均相对湿度为70%。意味着它处于Olgyay生物气候图和加拿大国家职业健康与安全资源(CCOHS)舒适区的上边缘,因此室内空间仍然不舒服,在温暖潮湿的气候下需要制冷才能进入舒适区。对有植被的西向窗户的照明测量结果显示,在下午02:45时,最高照度为350勒克斯,而对朝北的窗户,在上午07:30 -下午04:45时,最高照度为105 - 155勒克斯。因此,如果窗户外有植被,则需要增加电照明,因为照度低于SNI 03-6197-2011,设计工作室推荐750勒克斯。同时,用户从调查问卷中回答说,审美植被是自然元素的期望,阻止太阳辐射渗透到室内,减少眩光以增加视觉舒适度,同时不降低设计工作室视觉活动的充足亮度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
审稿时长
16 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信