Dosimetric Evaluation of Body Contour Changes to Target Volumes and Organs at Risk for Cervix and Head and Neck Radiotherapy Plans

Zhe Wu, Jun Yan, Xiaomei Chen, Dong Wang, Ke Liu, Z. Ming, Lin Wang, Bo Yu, Y. Pang
{"title":"Dosimetric Evaluation of Body Contour Changes to Target Volumes and Organs at Risk for Cervix and Head and Neck Radiotherapy Plans","authors":"Zhe Wu, Jun Yan, Xiaomei Chen, Dong Wang, Ke Liu, Z. Ming, Lin Wang, Bo Yu, Y. Pang","doi":"10.4236/ijmpcero.2020.93010","DOIUrl":null,"url":null,"abstract":"Purpose: To investigate how much dose discrepancy would be caused by the anatomy changes during the radiotherapy (RT) course. Methods: Ten cervical cancer and ten nasopharyngeal carcinoma (NPC) CT datasets from RT patients were enrolled. The body contour from different directions changed to simulate the weight loss or gain for cervical cancer patients, who had been treated with external-beam RT using intensity-modulated radiation therapy (IMRT) or volumetric modulated arc therapy (VMAT). Moreover, the body contour from facial and shoulder superior-inferior positional change had been also assessed for NPC patients using IMRT or VMAT. The new CT (n-CT) was generated by the body contour changes with different directions based on original CT datasets. The dosimetric parameters to target volumes and organs at risk (OARs) were evaluated in Eclipse based on n-CT. Results: The target volumes and OARs were influenced by the body contour changes. Body contour expansion resulted in coverage loss, whereas body contour shrinkage increased the dose to the OARs. These findings were generally consistent for both IMRT and VMAT plans. Over a course of research, the dose to 95% of the target volumes for cervical cancer decreased by up to 2.83% per cm for IMRT and 2.87% per cm for VMAT (P < 0.05). And the influence on H&N plans was that the dose to 95% of the target volumes (low risk regions) decreased by up to 4.45% per cm. Conclusions: The RT staff could determine whether resimulation and replaning or not according to which body contour directions were changed.","PeriodicalId":14028,"journal":{"name":"International Journal of Medical Physics, Clinical Engineering and Radiation Oncology","volume":"15 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Medical Physics, Clinical Engineering and Radiation Oncology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4236/ijmpcero.2020.93010","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To investigate how much dose discrepancy would be caused by the anatomy changes during the radiotherapy (RT) course. Methods: Ten cervical cancer and ten nasopharyngeal carcinoma (NPC) CT datasets from RT patients were enrolled. The body contour from different directions changed to simulate the weight loss or gain for cervical cancer patients, who had been treated with external-beam RT using intensity-modulated radiation therapy (IMRT) or volumetric modulated arc therapy (VMAT). Moreover, the body contour from facial and shoulder superior-inferior positional change had been also assessed for NPC patients using IMRT or VMAT. The new CT (n-CT) was generated by the body contour changes with different directions based on original CT datasets. The dosimetric parameters to target volumes and organs at risk (OARs) were evaluated in Eclipse based on n-CT. Results: The target volumes and OARs were influenced by the body contour changes. Body contour expansion resulted in coverage loss, whereas body contour shrinkage increased the dose to the OARs. These findings were generally consistent for both IMRT and VMAT plans. Over a course of research, the dose to 95% of the target volumes for cervical cancer decreased by up to 2.83% per cm for IMRT and 2.87% per cm for VMAT (P < 0.05). And the influence on H&N plans was that the dose to 95% of the target volumes (low risk regions) decreased by up to 4.45% per cm. Conclusions: The RT staff could determine whether resimulation and replaning or not according to which body contour directions were changed.
子宫颈和头颈部放射治疗计划中靶体积和危险器官的身体轮廓变化的剂量学评价
目的:探讨放射治疗过程中解剖结构的改变会引起多少剂量差异。方法:纳入10例宫颈癌和10例鼻咽癌(NPC) RT患者的CT数据集。从不同方向改变的身体轮廓来模拟宫颈癌患者的体重减轻或增加,他们接受了外束放疗,使用调强放疗(IMRT)或体积调制弧线治疗(VMAT)。此外,使用IMRT或VMAT评估鼻咽癌患者的面部和肩部上下位置变化的身体轮廓。在原始CT数据集的基础上,通过不同方向的人体轮廓变化生成新的CT (n-CT)。基于n-CT在Eclipse中评估靶体积和危险器官(OARs)的剂量学参数。结果:靶体积和桨叶受体廓变化的影响。体廓扩张导致覆盖损失,而体廓收缩则增加桨叶的剂量。这些发现在IMRT和VMAT计划中基本一致。在整个研究过程中,宫颈癌95%靶体积的剂量在IMRT和VMAT中分别下降了2.83% / cm和2.87% / cm (P < 0.05)。对H&N计划的影响是,95%的目标体积(低风险区域)的剂量每厘米最多减少4.45%。结论:RT工作人员可以根据身体轮廓方向的改变来判断是否重新模拟和重新规划。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信