The Capacity to Change the Lightness of Discolored Tooth Substrates by Means of Minimally Invasive Restorations: Perception by Dentists, Dental Technicians, and Laypersons
Kevser Pala, Andreas Bindl, Sven Mühlemann, Mutlu Özcan, Jürg Hüsler, Alexis Ioannidis
{"title":"The Capacity to Change the Lightness of Discolored Tooth Substrates by Means of Minimally Invasive Restorations: Perception by Dentists, Dental Technicians, and Laypersons","authors":"Kevser Pala, Andreas Bindl, Sven Mühlemann, Mutlu Özcan, Jürg Hüsler, Alexis Ioannidis","doi":"10.11607/ijp.7287","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the minimal ceramic thickness needed to increase the lightness by one value by means of glass-ceramic restorations perceived by dental technicians, dentists, and laypersons.</p><p><strong>Material and methods: </strong>A total of 15 assessment pairs (reference and test samples) were formed using glass-ceramic blocks in four different colors. Each assessment pair was comprised of two underground blocks differing in one value of lightness. On top of the underground blocks, glass-ceramic platelets were cemented in five different thicknesses (0.1 to 0.5 mm) and in the same color as the reference. Dental technicians, dentists, and laypersons (n = 41/group) were asked to determine the presence of a color difference between the two samples under standardized lighting conditions. The threshold ceramic thickness was defined as the thickness at which ≥ 50% of the evaluators were not able to perceive a difference within an assessment pair. The thresholds were analyzed, and groups were compared by applying chi-square test (P < .05).</p><p><strong>Results: </strong>The majority of dentists and dental technicians (> 50%) detected a lightness difference between the test and reference samples up to a ceramic thickness of 0.5 mm. The majority of laypersons (≥ 50%) did not perceive a lightness difference with ceramic thickness of 0.5 mm. If separated by the different color changes, the threshold ceramic thickness started at 0.4 mm and varied within the groups of evaluators and by the lightness of the assessed color.</p><p><strong>Conclusion: </strong>A considerable number of evaluators perceived a lightness difference when minimally invasive ceramic restorations of 0.5-mm thickness were applied. The threshold ceramic thickness, however, was reduced when the lightness of the substrate was lower.</p>","PeriodicalId":50292,"journal":{"name":"International Journal of Prosthodontics","volume":"36 1","pages":"7–12"},"PeriodicalIF":2.1000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Prosthodontics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.11607/ijp.7287","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 2
Abstract
Purpose: To evaluate the minimal ceramic thickness needed to increase the lightness by one value by means of glass-ceramic restorations perceived by dental technicians, dentists, and laypersons.
Material and methods: A total of 15 assessment pairs (reference and test samples) were formed using glass-ceramic blocks in four different colors. Each assessment pair was comprised of two underground blocks differing in one value of lightness. On top of the underground blocks, glass-ceramic platelets were cemented in five different thicknesses (0.1 to 0.5 mm) and in the same color as the reference. Dental technicians, dentists, and laypersons (n = 41/group) were asked to determine the presence of a color difference between the two samples under standardized lighting conditions. The threshold ceramic thickness was defined as the thickness at which ≥ 50% of the evaluators were not able to perceive a difference within an assessment pair. The thresholds were analyzed, and groups were compared by applying chi-square test (P < .05).
Results: The majority of dentists and dental technicians (> 50%) detected a lightness difference between the test and reference samples up to a ceramic thickness of 0.5 mm. The majority of laypersons (≥ 50%) did not perceive a lightness difference with ceramic thickness of 0.5 mm. If separated by the different color changes, the threshold ceramic thickness started at 0.4 mm and varied within the groups of evaluators and by the lightness of the assessed color.
Conclusion: A considerable number of evaluators perceived a lightness difference when minimally invasive ceramic restorations of 0.5-mm thickness were applied. The threshold ceramic thickness, however, was reduced when the lightness of the substrate was lower.
期刊介绍:
Official Journal of the European Association for Osseointegration (EAO), the International College of Prosthodontists (ICP), the German Society of Prosthodontics and Dental Materials Science (DGPro), and the Italian Academy of Prosthetic Dentistry (AIOP)
Prosthodontics demands a clinical research emphasis on patient- and dentist-mediated concerns in the management of oral rehabilitation needs. It is about making and implementing the best clinical decisions to enhance patients'' quality of life via applied biologic architecture - a role that far exceeds that of traditional prosthetic dentistry, with its emphasis on materials and techniques. The International Journal of Prosthodontics is dedicated to exploring and developing this conceptual shift in the role of today''s prosthodontist, clinician, and educator alike. The editorial board is composed of a distinguished team of leading international scholars.