Serum levels of lead and copper in a group of Egyptian children with bronchial asthma

IF 0.2 Q4 ALLERGY
Mohammad M. El Sherbeny, O. Behairy, O. Mohammad, Ahmad ElSayed
{"title":"Serum levels of lead and copper in a group of Egyptian children with bronchial asthma","authors":"Mohammad M. El Sherbeny, O. Behairy, O. Mohammad, Ahmad ElSayed","doi":"10.4314/EJPAI.V14I2","DOIUrl":null,"url":null,"abstract":"Background: Copper and lead are trace elements required for the activity of antioxidant enzymes and changes in their levels may lead to reduction in antioxidant activities in asthma. Objective: Our study aims to investigate the serum levels of copper and lead in asthmatic children in correlation to disease severity to anticipate their role as oxidant defenders in this disease. Methods: We enrolled 45 children who were divided into two groups: group 1 included 30 asthmatic children during disease quiescence and group 2 included 15 clinically healthy children matched for age and sex as a control group. Patients were subjected to: history taking, clinical examination, spirometry before and after bronchodilator therapy, complete blood counting, and measurement of serum levels of total IgE, copper and lead (in patients and controls). Results: Patients’ group had significantly higher serum levels of lead (mean 8.2±3.1 μg/dl) and copper (122±31.5 μg/dl) in comparison to controls (mean 5.7±2.3 μg/dl and103.3±21.1 μg/dl respectively). Serum lead and copper levels were higher among patients with moderate persistent asthma than those with mild asthma. Serum total IgE levels correlated positively with serum lead levels among the asthmatic children. However, serum lead and copper levels did not correlate with any of the measured pulmonary function parameters tested. Conclusion: Increased serum level of lead and copper were high in a group of children with bronchial asthma in children and this was more evident in moderate than mild cases. Keywords: children; trace elements; lead; copper; spirometry; bronchial asthma; antioxidants; severity","PeriodicalId":52068,"journal":{"name":"Egyptian Journal of Pediatric Allergy and Immunology","volume":null,"pages":null},"PeriodicalIF":0.2000,"publicationDate":"2016-11-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Egyptian Journal of Pediatric Allergy and Immunology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4314/EJPAI.V14I2","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ALLERGY","Score":null,"Total":0}
引用次数: 5

Abstract

Background: Copper and lead are trace elements required for the activity of antioxidant enzymes and changes in their levels may lead to reduction in antioxidant activities in asthma. Objective: Our study aims to investigate the serum levels of copper and lead in asthmatic children in correlation to disease severity to anticipate their role as oxidant defenders in this disease. Methods: We enrolled 45 children who were divided into two groups: group 1 included 30 asthmatic children during disease quiescence and group 2 included 15 clinically healthy children matched for age and sex as a control group. Patients were subjected to: history taking, clinical examination, spirometry before and after bronchodilator therapy, complete blood counting, and measurement of serum levels of total IgE, copper and lead (in patients and controls). Results: Patients’ group had significantly higher serum levels of lead (mean 8.2±3.1 μg/dl) and copper (122±31.5 μg/dl) in comparison to controls (mean 5.7±2.3 μg/dl and103.3±21.1 μg/dl respectively). Serum lead and copper levels were higher among patients with moderate persistent asthma than those with mild asthma. Serum total IgE levels correlated positively with serum lead levels among the asthmatic children. However, serum lead and copper levels did not correlate with any of the measured pulmonary function parameters tested. Conclusion: Increased serum level of lead and copper were high in a group of children with bronchial asthma in children and this was more evident in moderate than mild cases. Keywords: children; trace elements; lead; copper; spirometry; bronchial asthma; antioxidants; severity
一组埃及支气管哮喘患儿血清铅和铜水平
背景:铜和铅是抗氧化酶活性所必需的微量元素,其水平的变化可能导致哮喘患者抗氧化活性降低。目的:本研究旨在探讨哮喘儿童血清铜和铅水平与疾病严重程度的关系,以预测其在哮喘中作为氧化防御者的作用。方法:将45例患儿分为两组:1组30例处于疾病静止期的哮喘患儿,2组15例年龄、性别相匹配的临床健康患儿作为对照组。患者接受:病史记录、临床检查、支气管扩张剂治疗前后肺活量测定、全血细胞计数、血清总IgE、铜和铅水平测定(患者和对照组)。结果:患者组血铅(平均8.2±3.1 μg/dl)和铜(122±31.5 μg/dl)明显高于对照组(平均5.7±2.3 μg/dl和103.3±21.1 μg/dl)。中度持续性哮喘患者的血清铅和铜水平高于轻度哮喘患者。哮喘患儿血清总IgE水平与血铅水平呈正相关。然而,血清铅和铜水平与任何测量的肺功能参数测试无关。结论:支气管哮喘患儿血清铅、铜水平较高,且中重度患儿较轻重度患儿明显。关键词:儿童;微量元素;铅;铜;肺量测定法;支气管哮喘;抗氧化剂;严重程度
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
33.30%
发文量
19
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信