{"title":"A topology-based model for two-winding, shell-type, single-phase transformer inter-turn faults","authors":"L. Zhuang, B. Johnson, Xusheng Chen, E. William","doi":"10.1109/TDC.2016.7520078","DOIUrl":null,"url":null,"abstract":"This paper develops a topology-based model for representing two-winding, shell-type, single-phase transformer inter-turn faults. The principle of duality between the electric and magnetic equivalent circuits is concisely explained. The magnetic equivalent circuit of a two-winding, shell-type, single-phase transformer is extended to the magnetic circuit of a transformer with an inter-turn fault. The model is implemented in the electromagnetic transients program using built-in component models. The model is verified against results published for a 150kVA three-phase transformer and experimental testing on 55kVA three-phase transformer constructed for internal fault testing. While the developed model is for single-phase transformers, extending it to a topology-based model for three-phase, three-legged and five-legged transformers is straight forward. This model may find usage in transformer relay protection studies.","PeriodicalId":6497,"journal":{"name":"2016 IEEE/PES Transmission and Distribution Conference and Exposition (T&D)","volume":"45 1","pages":"1-5"},"PeriodicalIF":0.0000,"publicationDate":"2016-05-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE/PES Transmission and Distribution Conference and Exposition (T&D)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TDC.2016.7520078","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
This paper develops a topology-based model for representing two-winding, shell-type, single-phase transformer inter-turn faults. The principle of duality between the electric and magnetic equivalent circuits is concisely explained. The magnetic equivalent circuit of a two-winding, shell-type, single-phase transformer is extended to the magnetic circuit of a transformer with an inter-turn fault. The model is implemented in the electromagnetic transients program using built-in component models. The model is verified against results published for a 150kVA three-phase transformer and experimental testing on 55kVA three-phase transformer constructed for internal fault testing. While the developed model is for single-phase transformers, extending it to a topology-based model for three-phase, three-legged and five-legged transformers is straight forward. This model may find usage in transformer relay protection studies.