Comparison of Color Stability and Surface Roughness of 3D Printing Resin by Polishing Methods

Hee-Nam Kim, Yujin Kim, Jongsoo Kim, Joonhaeng Lee, M. Han, Jisun Shin, Jongbin Kim
{"title":"Comparison of Color Stability and Surface Roughness of 3D Printing Resin by Polishing Methods","authors":"Hee-Nam Kim, Yujin Kim, Jongsoo Kim, Joonhaeng Lee, M. Han, Jisun Shin, Jongbin Kim","doi":"10.5933/jkapd.2023.50.2.205","DOIUrl":null,"url":null,"abstract":"This study aimed to compare the color stability and surface roughness of three-dimensional (3D) printing resin according to polishing methods. 3D-printed resin specimens were fabricated at TC-80DP (Graphy, Seoul, Korea) with a stereolithography 3D printer, and the specimens were divided into three groups, each of which was not polished, was polished using Enhance®, and was polished using a Sof-LexTM disc. The CIE L*a*b* value and the surface roughness of each group were measured and immersed in artificial saliva and orange juice after 0, 1, 7, 30, and 60 days, and the color difference (ΔE*) was calculated. As a result of the study, no noticeable color change was observed in artificial saliva, but a noticeable color change was demonstrated in orange juice after 60 days of immersion, and the difference was significant. In the Sof-LexTM group, surface roughness according to the solution was found to be significantly higher in the orange juice than that in artificial saliva. No significant difference in color change was found according to the polishing method, but surface roughness was significantly lower in the Sof-LexTM group than both that of the unpolished group and that of the Enhance® group. Nevertheless, all groups exhibited clinically acceptable properties regardless of their higher surface roughness than the threshold for plaque accumulation. Overall, this study recommends utilizing Sof-LexTM for polishing 3D printing resin when used in primary anterior tooth coverage.","PeriodicalId":22818,"journal":{"name":"THE JOURNAL OF THE KOREAN ACADEMY OF PEDTATRIC DENTISTRY","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-05-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"THE JOURNAL OF THE KOREAN ACADEMY OF PEDTATRIC DENTISTRY","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5933/jkapd.2023.50.2.205","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This study aimed to compare the color stability and surface roughness of three-dimensional (3D) printing resin according to polishing methods. 3D-printed resin specimens were fabricated at TC-80DP (Graphy, Seoul, Korea) with a stereolithography 3D printer, and the specimens were divided into three groups, each of which was not polished, was polished using Enhance®, and was polished using a Sof-LexTM disc. The CIE L*a*b* value and the surface roughness of each group were measured and immersed in artificial saliva and orange juice after 0, 1, 7, 30, and 60 days, and the color difference (ΔE*) was calculated. As a result of the study, no noticeable color change was observed in artificial saliva, but a noticeable color change was demonstrated in orange juice after 60 days of immersion, and the difference was significant. In the Sof-LexTM group, surface roughness according to the solution was found to be significantly higher in the orange juice than that in artificial saliva. No significant difference in color change was found according to the polishing method, but surface roughness was significantly lower in the Sof-LexTM group than both that of the unpolished group and that of the Enhance® group. Nevertheless, all groups exhibited clinically acceptable properties regardless of their higher surface roughness than the threshold for plaque accumulation. Overall, this study recommends utilizing Sof-LexTM for polishing 3D printing resin when used in primary anterior tooth coverage.
抛光方法对3D打印树脂颜色稳定性和表面粗糙度的影响
本研究旨在比较不同抛光方法下3D打印树脂的颜色稳定性和表面粗糙度。在TC-80DP (Graphy, Seoul, Korea)用立体光刻3D打印机制作3D打印树脂样品,并将样品分为三组,每组不抛光,使用Enhance®抛光,使用soflextm光盘抛光。测量各组在0、1、7、30、60天后的CIE L*a*b*值和表面粗糙度,并浸泡在人工唾液和橙汁中,计算色差(ΔE*)。研究结果表明,人工唾液没有出现明显的颜色变化,而橙汁在浸泡60天后出现了明显的颜色变化,且差异显著。在soflextm组中,根据溶液发现橙汁中的表面粗糙度明显高于人工唾液中的表面粗糙度。根据抛光方法,颜色变化没有明显差异,但表面粗糙度在soflextm组明显低于未抛光组和Enhance®组。尽管如此,所有组均表现出临床可接受的特性,无论其表面粗糙度高于斑块积聚的阈值。总的来说,本研究推荐使用soflextm抛光3D打印树脂用于初级前牙覆盖。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信