{"title":"Structural modal parameter identification incorporating with semi-active piezoelectric control","authors":"Y. Hara, H. Asanuma, Keisuke Otsuka, Kanjuro Makihara","doi":"10.1117/12.2656930","DOIUrl":null,"url":null,"abstract":"In this paper, we present a novel structural identification method using semi-active inputs generated by piezoelectric transducers. Structural identification using input and output information provides an accurate structural model. Conventional identification uses a maximum-length sequence, whose signal shape is similar to a square wave, as input. To generate inputs suitable for identification, several devices are required. These devices consume a lot of energy. If inputs are generated by a small number and simple design devices with low consumption, structural identification will be more practical. Piezoelectric semi-active control has been used in the research field of vibration control. This control generates a semi-active input whose signal shape is similar to a square wave. The semi-active input is generated by a simple circuit. The generation of the semi-active input consumes little energy. Therefore, the semi-active input has the potential to be used as an identification input instead of the maximum-length sequence. The property of the semi-active input is related to the generation strategy. This paper proposes a novel strategy to generate a semi-active input suitable for identification. Due to the unique mechanism of semi-active input generation, the novel strategy sometimes has the problem of generating semi-active inputs that are not suitable for identification. This paper discusses the reason and the solution to this problem. The feasibility of semi-active identification is presented through the numerical simulation and validation experiment. The identification result of the proposed method was close to the exact model. The proposed method achieved a 99% reduction in energy consumption.","PeriodicalId":89272,"journal":{"name":"Smart structures and materials. Nondestructive evaluation for health monitoring and diagnostics","volume":"18 1","pages":"124830H - 124830H-15"},"PeriodicalIF":0.0000,"publicationDate":"2023-04-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Smart structures and materials. Nondestructive evaluation for health monitoring and diagnostics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2656930","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In this paper, we present a novel structural identification method using semi-active inputs generated by piezoelectric transducers. Structural identification using input and output information provides an accurate structural model. Conventional identification uses a maximum-length sequence, whose signal shape is similar to a square wave, as input. To generate inputs suitable for identification, several devices are required. These devices consume a lot of energy. If inputs are generated by a small number and simple design devices with low consumption, structural identification will be more practical. Piezoelectric semi-active control has been used in the research field of vibration control. This control generates a semi-active input whose signal shape is similar to a square wave. The semi-active input is generated by a simple circuit. The generation of the semi-active input consumes little energy. Therefore, the semi-active input has the potential to be used as an identification input instead of the maximum-length sequence. The property of the semi-active input is related to the generation strategy. This paper proposes a novel strategy to generate a semi-active input suitable for identification. Due to the unique mechanism of semi-active input generation, the novel strategy sometimes has the problem of generating semi-active inputs that are not suitable for identification. This paper discusses the reason and the solution to this problem. The feasibility of semi-active identification is presented through the numerical simulation and validation experiment. The identification result of the proposed method was close to the exact model. The proposed method achieved a 99% reduction in energy consumption.
结合半主动压电控制的结构模态参数辨识
本文提出了一种利用压电换能器产生的半主动输入进行结构识别的新方法。使用输入和输出信息的结构识别提供了准确的结构模型。传统的识别使用最大长度序列,其信号形状类似于方波,作为输入。为了产生适合识别的输入,需要几个设备。这些设备消耗大量能源。如果输入是由数量少、设计简单、消耗低的装置产生的,结构识别将更加实用。压电半主动控制已被应用于振动控制的研究领域。该控制产生一个半主动输入,其信号形状类似于方波。半有源输入由一个简单的电路产生。半主动输入的产生消耗很少的能量。因此,半主动输入有可能被用作识别输入,而不是最大长度序列。半主动输入的特性与发电策略有关。本文提出了一种生成适合于识别的半主动输入的新策略。由于半主动输入生成机制的独特性,该策略有时会产生不适合识别的半主动输入问题。本文探讨了造成这一问题的原因及解决方法。通过数值模拟和验证实验,证明了半主动识别的可行性。该方法的识别结果与实际模型较为接近。所提出的方法实现了99%的能源消耗减少。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信