Acoustic microscopy with electronic scanning in one direction

J. Cheeke, L. Germain
{"title":"Acoustic microscopy with electronic scanning in one direction","authors":"J. Cheeke, L. Germain","doi":"10.1109/ULTSYM.1989.67105","DOIUrl":null,"url":null,"abstract":"A method for electronic scanning in acoustic microscopy and ultrasonic imaging is described. A wedge transducer is used to illuminate a standard cylindrical lens. As the resonant frequency of the transducer varies with position, it is possible to sweep the focal spot down the line by changing the frequency. A typical acoustic image is given as well as detailed considerations on the resolution of the device. Experimental results on reflection from a scattering object indicate that the effective excitation width in the transducer is the main effect controlling the resolution.<<ETX>>","PeriodicalId":89469,"journal":{"name":"Proceedings. IEEE Ultrasonics Symposium","volume":"30 1","pages":"837-840 vol.2"},"PeriodicalIF":0.0000,"publicationDate":"1989-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings. IEEE Ultrasonics Symposium","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ULTSYM.1989.67105","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

A method for electronic scanning in acoustic microscopy and ultrasonic imaging is described. A wedge transducer is used to illuminate a standard cylindrical lens. As the resonant frequency of the transducer varies with position, it is possible to sweep the focal spot down the line by changing the frequency. A typical acoustic image is given as well as detailed considerations on the resolution of the device. Experimental results on reflection from a scattering object indicate that the effective excitation width in the transducer is the main effect controlling the resolution.<>
在一个方向上进行电子扫描的声学显微镜
描述了一种声学显微镜和超声成像中的电子扫描方法。楔形换能器用于照亮标准圆柱形透镜。由于换能器的谐振频率随位置的变化而变化,因此可以通过改变频率将焦点光斑沿直线扫过。给出了一个典型的声学图像,并详细考虑了该装置的分辨率。对散射物体反射的实验结果表明,传感器的有效激发宽度是控制分辨率的主要因素。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书