Effects of a Low-Intensity Laser on Dental Implant Osseointegration: Removal Torque and Resonance Frequency Analysis in Rabbits.

A. Blay, Claudia C Blay, Samy Tunchel, S. Gehrke, J. Shibli, E. B. Groth, D. Zezell
{"title":"Effects of a Low-Intensity Laser on Dental Implant Osseointegration: Removal Torque and Resonance Frequency Analysis in Rabbits.","authors":"A. Blay, Claudia C Blay, Samy Tunchel, S. Gehrke, J. Shibli, E. B. Groth, D. Zezell","doi":"10.1563/aaid-joi-D-15-00064","DOIUrl":null,"url":null,"abstract":"The objective of this study was to investigate how a low-intensity laser affects the stability and reverse torque resistance of dental implants installed in the tibia of rabbits. Thirty rabbits received 60 dental implants with the same design and surface treatment, one in each proximal metaphysis of the tibia. Three groups were prepared (n = 10 animals each): conventional osseointegration without treatment (control group), surgical sites irradiated with a laser beam emitted in the visible range of 680 nm (Lg1 group), surgical sites irradiated with a laser beam with a wavelength in the infrared range of 830 nm (Lg2 group). Ten irradiation sessions were performed 48 hours apart; the first session was during the immediate postoperative period. Irradiation energy density was 4 J/cm(2) per point in 2 points on each side of the tibias. The resonance frequency and removal torque values were measured at 2 time points after the implantations (3 and 6 weeks). Both laser groups (Lg1 and Lg2) presented a significant difference between resonance frequency analysis values at the baseline and the values obtained after 3 and 6 weeks (P > .05). Although the removal torque values of all groups increased after 6 weeks (P < .05), both laser groups presented greater mean values than those of the control group (P < .01). Photobiomodulation using laser irradiation with wavelengths of 680 and 830 nm had a better degree of bone integration than the control group after 6 weeks of observation time.","PeriodicalId":77634,"journal":{"name":"The International journal of oral implantology : implantologist","volume":"11 1","pages":"316-20"},"PeriodicalIF":0.0000,"publicationDate":"2016-08-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The International journal of oral implantology : implantologist","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1563/aaid-joi-D-15-00064","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13

Abstract

The objective of this study was to investigate how a low-intensity laser affects the stability and reverse torque resistance of dental implants installed in the tibia of rabbits. Thirty rabbits received 60 dental implants with the same design and surface treatment, one in each proximal metaphysis of the tibia. Three groups were prepared (n = 10 animals each): conventional osseointegration without treatment (control group), surgical sites irradiated with a laser beam emitted in the visible range of 680 nm (Lg1 group), surgical sites irradiated with a laser beam with a wavelength in the infrared range of 830 nm (Lg2 group). Ten irradiation sessions were performed 48 hours apart; the first session was during the immediate postoperative period. Irradiation energy density was 4 J/cm(2) per point in 2 points on each side of the tibias. The resonance frequency and removal torque values were measured at 2 time points after the implantations (3 and 6 weeks). Both laser groups (Lg1 and Lg2) presented a significant difference between resonance frequency analysis values at the baseline and the values obtained after 3 and 6 weeks (P > .05). Although the removal torque values of all groups increased after 6 weeks (P < .05), both laser groups presented greater mean values than those of the control group (P < .01). Photobiomodulation using laser irradiation with wavelengths of 680 and 830 nm had a better degree of bone integration than the control group after 6 weeks of observation time.
低强度激光对家兔种植体骨整合的影响:去除扭矩和共振频率分析。
本研究的目的是研究低强度激光如何影响兔胫骨内种植体的稳定性和抗反扭矩。30只家兔采用相同的设计和表面处理方法,在胫骨近端干骺端各放置一颗种植体。制备三组(n = 10只):未经治疗的常规骨整合(对照组)、680 nm可见光激光照射(Lg1组)、830 nm红外激光照射(Lg2组)。10次照射间隔48小时;第一次是在术后立即进行。胫骨两侧各2个点辐照能量密度为4 J/cm(2) /点。在植入后2个时间点(3周和6周)测量共振频率和去除扭矩值。两个激光组(Lg1和Lg2)基线时的共振频率分析值与第3周和第6周时的共振频率分析值比较差异有统计学意义(P > 0.05)。虽然6周后各组的去除扭矩值均有所增加(P < 0.05),但两组的平均值均高于对照组(P < 0.01)。观察6周后,680 nm和830 nm激光照射光生物调节组骨整合程度优于对照组。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书