Application of error analysis in the evaluation of electron beam potentials from the ratio of filtered X-ray detectors

J. Rauch
{"title":"Application of error analysis in the evaluation of electron beam potentials from the ratio of filtered X-ray detectors","authors":"J. Rauch","doi":"10.1109/PPC.1999.823586","DOIUrl":null,"url":null,"abstract":"Statistical analysis was applied to a set of filtered X-ray detectors to determine the most probable electron beam potential using the estimated variance of each measured ratio. Although this technique was used for potential measurements at both the Defense Threat Reduction Agency ACE 4 accelerator located at Maxwell Technologies and the NRL HAWK accelerator in Washington, DC, only the HAWK data are shown to illustrate the procedure. A weighting factor for each potential measurement was obtained by combining the estimates of the variances for each X-ray signal measurement used to obtain the ratio. The variance in the measured ratio was weighted by the rate of change of the potential with the specific ratio to make the weighting factor applicable to the potential measurement. The electron beam potential waveform measured by this ratio procedure was compared with the electrical probe measurements of the HAWK beam potential.","PeriodicalId":11209,"journal":{"name":"Digest of Technical Papers. 12th IEEE International Pulsed Power Conference. (Cat. No.99CH36358)","volume":"35 1","pages":"612-614 vol.2"},"PeriodicalIF":0.0000,"publicationDate":"1999-06-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Digest of Technical Papers. 12th IEEE International Pulsed Power Conference. (Cat. No.99CH36358)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PPC.1999.823586","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Statistical analysis was applied to a set of filtered X-ray detectors to determine the most probable electron beam potential using the estimated variance of each measured ratio. Although this technique was used for potential measurements at both the Defense Threat Reduction Agency ACE 4 accelerator located at Maxwell Technologies and the NRL HAWK accelerator in Washington, DC, only the HAWK data are shown to illustrate the procedure. A weighting factor for each potential measurement was obtained by combining the estimates of the variances for each X-ray signal measurement used to obtain the ratio. The variance in the measured ratio was weighted by the rate of change of the potential with the specific ratio to make the weighting factor applicable to the potential measurement. The electron beam potential waveform measured by this ratio procedure was compared with the electrical probe measurements of the HAWK beam potential.
误差分析在评价过滤x射线探测器比例电子束电位中的应用
统计分析应用于一组过滤x射线探测器,以确定最可能的电子束势,利用估计方差的每个测量比率。尽管该技术已在麦克斯韦技术公司的国防威胁减少局ACE 4加速器和华盛顿特区的NRL HAWK加速器上用于潜在测量,但仅显示HAWK数据来说明该过程。通过结合用于获得比率的每个x射线信号测量的方差估计值,获得每个潜在测量的权重因子。将测量比值的方差以电势随特定比值的变化率进行加权,使加权系数适用于电势测量。用该比值法测得的电子束电位波形与电探针测得的HAWK电子束电位波形进行了比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信