Comparison of performance characteristics of SCR and ECM controlled series fan powered terminal units

D. O’Neal, J. Edmondson, Peng Yin
{"title":"Comparison of performance characteristics of SCR and ECM controlled series fan powered terminal units","authors":"D. O’Neal, J. Edmondson, Peng Yin","doi":"10.1080/10789669.2013.850959","DOIUrl":null,"url":null,"abstract":"Airflow, efficiency, power, and power quality characteristics were evaluated for two variable air volume series fan powered terminal units. The power and power quality data included real power, power/airflow, apparent power, harmonic frequencies, and total harmonic distortion. Each unit had the same sized primary air inlet and were provided by the same manufacturer. One unit had a motor controlled by a silicon controlled rectifier and the other had an electronically commutated motor. Data were collected at a fixed downstream static pressure and a range of upstream static pressures, primary inlet damper positions, and input controller voltages. Both controllers maintained a nearly constant fan airflow as the primary air was varied. Fan/motor efficiencies were low (below 35%) and increased with fan static pressures. The electronically commutated motor unit had efficiencies as much as four times higher than the silicon controlled rectifier controlled unit which was reflected in much lower power draws. The electronically commuted fan/motor unit had the lowest apparent power at airflows below approximately 1000 ft3/min (0.47 m3/s). For both units, the total power harmonic distortion was less than 1%. The performance data indicated a major advantage of units with electronically commutated motors.","PeriodicalId":13238,"journal":{"name":"HVAC&R Research","volume":"17 2 1","pages":"194 - 202"},"PeriodicalIF":0.0000,"publicationDate":"2014-01-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"HVAC&R Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/10789669.2013.850959","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

Airflow, efficiency, power, and power quality characteristics were evaluated for two variable air volume series fan powered terminal units. The power and power quality data included real power, power/airflow, apparent power, harmonic frequencies, and total harmonic distortion. Each unit had the same sized primary air inlet and were provided by the same manufacturer. One unit had a motor controlled by a silicon controlled rectifier and the other had an electronically commutated motor. Data were collected at a fixed downstream static pressure and a range of upstream static pressures, primary inlet damper positions, and input controller voltages. Both controllers maintained a nearly constant fan airflow as the primary air was varied. Fan/motor efficiencies were low (below 35%) and increased with fan static pressures. The electronically commutated motor unit had efficiencies as much as four times higher than the silicon controlled rectifier controlled unit which was reflected in much lower power draws. The electronically commuted fan/motor unit had the lowest apparent power at airflows below approximately 1000 ft3/min (0.47 m3/s). For both units, the total power harmonic distortion was less than 1%. The performance data indicated a major advantage of units with electronically commutated motors.
可控硅与ECM控制串联风机供电终端的性能特性比较
对两个可变风量系列风扇驱动的终端单元的气流、效率、功率和电能质量特性进行了评估。功率和电能质量数据包括实际功率、功率/气流、视在功率、谐波频率和总谐波失真。每个机组都有相同尺寸的一次进气口,并由同一制造商提供。一个单元有一个由可控硅整流器控制的电机,另一个单元有一个电子换向电机。在固定的下游静压和一系列上游静压、主入口阻尼器位置和输入控制器电压下收集数据。当一次空气变化时,两个控制器都保持一个几乎恒定的风扇气流。风扇/电机效率很低(低于35%),并且随着风扇静压的增加而增加。电子换向电机单元的效率是硅控制整流器控制单元的四倍,这反映在更低的功耗上。当气流低于约1000 ft3/min (0.47 m3/s)时,电子换向风扇/电机单元的视在功率最低。两个机组的总功率谐波畸变均小于1%。性能数据表明,具有电子换向电机的单位具有主要优势。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
HVAC&R Research
HVAC&R Research 工程技术-工程:机械
自引率
0.00%
发文量
0
审稿时长
3 months
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信