Effect of Different Proportions of Courtyard Buildings in Hot-Dry Climate on Energy Consumption (Case Study: Traditional Courtyard Houses of Kerman, Iran)

N. Tayari, M. Nikpour
{"title":"Effect of Different Proportions of Courtyard Buildings in Hot-Dry Climate on Energy Consumption (Case Study: Traditional Courtyard Houses of Kerman, Iran)","authors":"N. Tayari, M. Nikpour","doi":"10.5829/ijee.2022.13.01.05","DOIUrl":null,"url":null,"abstract":"One of the crucial issues in early stages of designing process of a building is a lack of architects’ knowledge about the energy consumption in different forms of building with different proportions, especially in central courtyard forms. The purpose of this research is to investigate the effectiveness of the ratio of perimeter to the height of the courtyard (R1) and the ratio of width to length of the courtyard (R2) on energy consumption. In the first step of this research, different proportions of central courtyard with different R1 and R2 were simulated in DesignBuilder software. Then, multi linear regression was used to find out the effect of different proportions (R1 and R2) on energy consumption through SPSS software. Finally, the effect of R1 and R 2 ratio on energy consumption was validated through investigating six existing central courtyard forms. The result demonstrated that the effective coefficient of the R1 and R2 ratio on energy consumption were -25.41 and 62.69 respectively. Findings of this research help architects to achieve relative acknowledge about the energy consumption of different proportions of the courtyard forms for creating more energy efficient forms. doi : 10.5829/ijee.2022.13.01.05","PeriodicalId":14542,"journal":{"name":"Iranian Journal of Energy and Environment","volume":"32 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iranian Journal of Energy and Environment","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5829/ijee.2022.13.01.05","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

One of the crucial issues in early stages of designing process of a building is a lack of architects’ knowledge about the energy consumption in different forms of building with different proportions, especially in central courtyard forms. The purpose of this research is to investigate the effectiveness of the ratio of perimeter to the height of the courtyard (R1) and the ratio of width to length of the courtyard (R2) on energy consumption. In the first step of this research, different proportions of central courtyard with different R1 and R2 were simulated in DesignBuilder software. Then, multi linear regression was used to find out the effect of different proportions (R1 and R2) on energy consumption through SPSS software. Finally, the effect of R1 and R 2 ratio on energy consumption was validated through investigating six existing central courtyard forms. The result demonstrated that the effective coefficient of the R1 and R2 ratio on energy consumption were -25.41 and 62.69 respectively. Findings of this research help architects to achieve relative acknowledge about the energy consumption of different proportions of the courtyard forms for creating more energy efficient forms. doi : 10.5829/ijee.2022.13.01.05
干热气候下不同比例四合院建筑对能耗的影响(以伊朗克尔曼传统四合院为例)
在建筑设计的早期阶段,建筑师对不同比例的建筑形式,特别是中央庭院形式的能耗缺乏认识是一个关键问题。本研究的目的是调查庭院周长比(R1)和庭院宽长比(R2)对能耗的影响。在本研究的第一步,在DesignBuilder软件中模拟了不同比例的R1和R2的中央庭院。然后通过SPSS软件进行多元线性回归,找出不同比例(R1和R2)对能耗的影响。最后,通过对六种现有中央庭院形式的调查,验证了R1和r2比例对能耗的影响。结果表明,R1和R2比值对能耗的有效系数分别为-25.41和62.69。本研究的发现有助于建筑师对不同比例的庭院形式的能耗有一个相对的认识,从而创造出更节能的形式。Doi: 10.5829/ijee.2022.13.01.05
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信