Analysis of The Effect of Ambient Temperature and Loading on Power Transformers Ageing (Study Case of 3rd Power Transformer in Cikupa Substation)

Nur Al Anshari Munir, Yogasmana Al Mustafa, Fransileo Siagian
{"title":"Analysis of The Effect of Ambient Temperature and Loading on Power Transformers Ageing (Study Case of 3rd Power Transformer in Cikupa Substation)","authors":"Nur Al Anshari Munir, Yogasmana Al Mustafa, Fransileo Siagian","doi":"10.1109/ICHVEPS47643.2019.9011153","DOIUrl":null,"url":null,"abstract":"Power transformer is one of the most important and vital equipment in the substation. Power Transformers in Indonesia are mostly designed to refer to IEC standards. according to the IEC standard, power transformers are used at an ambient temperature of 20 °C. While as a tropical country, the average temperature in Indonesia is around 30 °C. Environmental temperature differences in design and real conditions make a transformer very risky to operate to reach its maximum capacity. Because of this, the transformer's operating must be adjusted. With a higher ambient temperature plus a higher load, the ageing of the transformer is also faster. The age of the transformer can be affected by the insulation of the winding and the condition of oil transformers.This research studies the effect of loading and ambient temperature which can reduce the lifetime of the transformer. The transformer which is the object of the research is 3rd power transformer in the Cikupa Substation.The results showed a decrease in transformer loading capacity at ambient temperatures above 20 °C. with the rate of increase 1,06% - 1,2% for ONAN condition and 0,87% - 0,96% for ONAF condition in the ambient temperature range 21 °C - 35 °C.","PeriodicalId":6677,"journal":{"name":"2019 2nd International Conference on High Voltage Engineering and Power Systems (ICHVEPS)","volume":"23 1","pages":"1-6"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 2nd International Conference on High Voltage Engineering and Power Systems (ICHVEPS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHVEPS47643.2019.9011153","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Power transformer is one of the most important and vital equipment in the substation. Power Transformers in Indonesia are mostly designed to refer to IEC standards. according to the IEC standard, power transformers are used at an ambient temperature of 20 °C. While as a tropical country, the average temperature in Indonesia is around 30 °C. Environmental temperature differences in design and real conditions make a transformer very risky to operate to reach its maximum capacity. Because of this, the transformer's operating must be adjusted. With a higher ambient temperature plus a higher load, the ageing of the transformer is also faster. The age of the transformer can be affected by the insulation of the winding and the condition of oil transformers.This research studies the effect of loading and ambient temperature which can reduce the lifetime of the transformer. The transformer which is the object of the research is 3rd power transformer in the Cikupa Substation.The results showed a decrease in transformer loading capacity at ambient temperatures above 20 °C. with the rate of increase 1,06% - 1,2% for ONAN condition and 0,87% - 0,96% for ONAF condition in the ambient temperature range 21 °C - 35 °C.
环境温度和负荷对电力变压器老化的影响分析(以茨库帕变电站3号电力变压器为例)
电力变压器是变电站中最重要、最重要的设备之一。印度尼西亚的电力变压器大多参照IEC标准设计。根据IEC标准,电力变压器的使用环境温度为20℃。而作为一个热带国家,印度尼西亚的平均气温在30°C左右。在设计和实际条件下的环境温度差异使得变压器在达到其最大容量时非常危险。因此,必须对变压器的运行进行调整。环境温度越高,负载越高,变压器的老化也越快。变压器的使用年限会受到绕组绝缘和油变压器状况的影响。本文研究了负载和环境温度对变压器寿命的影响。本文的研究对象是慈库帕变电站的3号电力变压器。结果表明,在环境温度高于20°C时,变压器的负载能力下降。在环境温度21℃~ 35℃范围内,在ONAN条件下增加1.06% ~ 1.2%,在ONAF条件下增加0.87% ~ 0.96%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信