D. Naylor, I. Veenendaal, T. Fulton, B. Gom, Adam J. Christiansen, W. Jellema, C. Feenstra, M. Eggens, P. Ade
{"title":"First light results from a novel cryogenic Fabry-Pérot interferometer","authors":"D. Naylor, I. Veenendaal, T. Fulton, B. Gom, Adam J. Christiansen, W. Jellema, C. Feenstra, M. Eggens, P. Ade","doi":"10.1109/IRMMW-THz.2019.8874094","DOIUrl":null,"url":null,"abstract":"The sensitivity of state-of-the-art superconducting far-infrared detectors is such that astronomical observations at these wavelengths are limited by photon noise from the astronomical source unless a method of restricting the spectral bandpass is employed. One such method is to use a high resolution Fabry-Perot interferometer (FPI) in conjunction with a lower resolution, post-dispersing system, such as a grating spectrometer. The resonant wavelength of an FPI is typically tuned by changing the spacing or medium between the parallel reflecting plates of the etalon. We previously reported on a novel design in which the wavelength is tuned by scanning the angle of incidence, which simplifies the cryo-mechanical design, actuation and metrology. Here we present first light results from the realized instrument.","PeriodicalId":6686,"journal":{"name":"2019 44th International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz)","volume":"50 1","pages":"1-2"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 44th International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IRMMW-THz.2019.8874094","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The sensitivity of state-of-the-art superconducting far-infrared detectors is such that astronomical observations at these wavelengths are limited by photon noise from the astronomical source unless a method of restricting the spectral bandpass is employed. One such method is to use a high resolution Fabry-Perot interferometer (FPI) in conjunction with a lower resolution, post-dispersing system, such as a grating spectrometer. The resonant wavelength of an FPI is typically tuned by changing the spacing or medium between the parallel reflecting plates of the etalon. We previously reported on a novel design in which the wavelength is tuned by scanning the angle of incidence, which simplifies the cryo-mechanical design, actuation and metrology. Here we present first light results from the realized instrument.