Accuracy and Internal Fit of 3D printed Occlusal Splint, according to the printing position

M. T. Vasques, D. Laganá
{"title":"Accuracy and Internal Fit of 3D printed Occlusal Splint, according to the printing position","authors":"M. T. Vasques, D. Laganá","doi":"10.11606/ISSN.2357-8041.CLRD.2018.148012","DOIUrl":null,"url":null,"abstract":"Understanding the importance of 3D printing strategies is a key to obtain predictable, optimized and consistent dental appliances using digital technologies. This study aims to present the influence of printing orientation on the intraoral fit of full arch coverage splints. Splints were designed for two patients using the CAD software and printed in a SLA 3D printer with different orientations (0, 30, and 90 degrees), and the internal fit was checked on patients’ mouth. Differen­ces between the fit of the splints were verified, with the worst results for 90º oriented splints, although more detailed studies are recommended by the authors. \nDESCRIPTORS | Three-Dimensional Printing; Accuracy; Dimensional Measurement; Occlusal Splint; Print Orientation.","PeriodicalId":10204,"journal":{"name":"Clinical and Laboratorial Research in Dentistry","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2018-10-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical and Laboratorial Research in Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11606/ISSN.2357-8041.CLRD.2018.148012","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

Abstract

Understanding the importance of 3D printing strategies is a key to obtain predictable, optimized and consistent dental appliances using digital technologies. This study aims to present the influence of printing orientation on the intraoral fit of full arch coverage splints. Splints were designed for two patients using the CAD software and printed in a SLA 3D printer with different orientations (0, 30, and 90 degrees), and the internal fit was checked on patients’ mouth. Differen­ces between the fit of the splints were verified, with the worst results for 90º oriented splints, although more detailed studies are recommended by the authors. DESCRIPTORS | Three-Dimensional Printing; Accuracy; Dimensional Measurement; Occlusal Splint; Print Orientation.
3D打印咬合夹板的精度和内部配合,根据打印位置
了解3D打印策略的重要性是使用数字技术获得可预测、优化和一致的牙科器械的关键。本研究旨在探讨印刷方向对全弓覆盖夹板口腔内贴合的影响。使用CAD软件为两名患者设计夹板,并在SLA 3D打印机上以不同的方向(0度,30度和90度)打印,并在患者的口腔上检查内部配合度。夹板贴合的差异得到了验证,90º导向夹板的结果最差,尽管作者建议进行更详细的研究。描述语|三维打印;准确;尺寸测量;咬合的夹板;打印方向。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
文献相关原料
公司名称 产品信息 采购帮参考价格
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信