Evaluation of ultrasound examination informativity in diagnosing retinoblastoma

Q4 Medicine
Y. V. Artemenko, T. R. Panferova, T. Ushakova, E. Mikhailova
{"title":"Evaluation of ultrasound examination informativity in diagnosing retinoblastoma","authors":"Y. V. Artemenko, T. R. Panferova, T. Ushakova, E. Mikhailova","doi":"10.21682/2311-1267-2023-10-1-49-56","DOIUrl":null,"url":null,"abstract":"The aim of this work is to evaluate the informativity of the ultrasound (US) in detecting retinoblastoma (RB) and the local invasion of the tumor in children using modern multi-purpose ultrasound scanners.Materials and methods. This study included 108 patients (216 eyes) examined for suspected RB. RB was diagnosed in 91 patients, 60 children had unilateral tumor, 31 – bilateral tumor (122 eyes). In the remaining 17 children (20 eyes damaged), different non-tumor pathology of the eye was revealed. Among 122 eyes affected by RB, 51 were removed with subsequent histological examination. 27 eyes were removed before treatment, 24 – after chemotherapy.Results. In our study the informativity of ultrasound in detecting RB are: sensitivity – 98.4 %, specificity – 96.8 %, accuracy – 97.7 %. Sensitivity, specificity and accuracy in assessing tumor invasion to the anterior segment of the eye are 36.4 %, 95.0 % and 82.4 % respectively, to the vitreous body – 97.7 %, 100 % and 97.9 %, to the optic nerve – 54.5 %, 57.1 % and 54.9 %.Conclusion. US examination using linear transducers of 9–18 MHz is highly informative in detecting RB, however, some indicators of the effectiveness in assessing local invasion are not high enough, due to the technical possibilities of the method. One possible way to improve the informativity – to use deep sedation during US examination.","PeriodicalId":52396,"journal":{"name":"Russian Journal of Pediatric Hematology and Oncology","volume":"67 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Russian Journal of Pediatric Hematology and Oncology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21682/2311-1267-2023-10-1-49-56","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

The aim of this work is to evaluate the informativity of the ultrasound (US) in detecting retinoblastoma (RB) and the local invasion of the tumor in children using modern multi-purpose ultrasound scanners.Materials and methods. This study included 108 patients (216 eyes) examined for suspected RB. RB was diagnosed in 91 patients, 60 children had unilateral tumor, 31 – bilateral tumor (122 eyes). In the remaining 17 children (20 eyes damaged), different non-tumor pathology of the eye was revealed. Among 122 eyes affected by RB, 51 were removed with subsequent histological examination. 27 eyes were removed before treatment, 24 – after chemotherapy.Results. In our study the informativity of ultrasound in detecting RB are: sensitivity – 98.4 %, specificity – 96.8 %, accuracy – 97.7 %. Sensitivity, specificity and accuracy in assessing tumor invasion to the anterior segment of the eye are 36.4 %, 95.0 % and 82.4 % respectively, to the vitreous body – 97.7 %, 100 % and 97.9 %, to the optic nerve – 54.5 %, 57.1 % and 54.9 %.Conclusion. US examination using linear transducers of 9–18 MHz is highly informative in detecting RB, however, some indicators of the effectiveness in assessing local invasion are not high enough, due to the technical possibilities of the method. One possible way to improve the informativity – to use deep sedation during US examination.
超声检查对视网膜母细胞瘤诊断的信息性评价
本研究的目的是评估超声(US)在使用现代多用途超声扫描仪检测儿童视网膜母细胞瘤(RB)和肿瘤局部侵袭方面的信息性。材料和方法。本研究纳入108例(216只眼)疑似RB检查。91例确诊为RB,其中单侧肿瘤60例,双侧肿瘤31例(122眼)。其余17例患儿(20只眼受损)的眼非肿瘤病理表现不同。在122只受RB影响的眼睛中,51只在随后的组织学检查中被切除。治疗前切除27只眼,化疗后切除24只眼。在我们的研究中,超声检测RB的信息性为:灵敏度98.4%,特异性96.8%,准确性97.7%。肿瘤侵袭眼前段的敏感性、特异性和准确性分别为36.4%、95.0%和82.4%,对玻璃体的敏感性为97.7%、100%和97.9%,对视神经的敏感性为54.5%、57.1%和54.9%。使用9-18 MHz线性换能器的US检查在检测RB方面具有很高的信息量,然而,由于该方法的技术可能性,评估局部入侵有效性的一些指标不够高。一种可能的方法是在美国检查时使用深度镇静。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Russian Journal of Pediatric Hematology and Oncology
Russian Journal of Pediatric Hematology and Oncology Medicine-Pediatrics, Perinatology and Child Health
CiteScore
0.40
自引率
0.00%
发文量
36
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信