{"title":"Experimental investigation of a one-level eight-channel cyclone-separator incorporating quarter-rings","authors":"A. Chlebnikovas","doi":"10.2298/hemind210307024c","DOIUrl":null,"url":null,"abstract":"The main aim of this investigation was an experimental analysis of the air\n cleaning efficiency in a mock-up next-generation air cleaning device -\n one-level 8-channel industrial cyclone-separator with quarter-rings - while\n changing parameters of the inner structure and the assessment of the effects\n of dispersion of particulate matter. Therefore, the research was carried out\n in two stages: the first stage covered the analysis of the efficiency of the\n multi-channel cyclone with particulate matter of <20 and <50 ?m. During the\n second stage, a cascade impactor was used to measure the particle collection\n efficiency in the multi-channel cyclone by fractions: PM1, PM2.5 and PM10.\n Results of the tests with using the cascade impactor were compared to show\n changes in the PM composition before and after the multi-channel\n cyclone-separator. According to the obtained experimental data, the\n one-level 8-channel cyclone-separator collects 70 to 80 % of PM up to 10 ?m\n in size, 45 to 60 % of PM up to 2.5 ?m in size and 21 to 25 % of PM up to 1\n ?m in size.","PeriodicalId":9933,"journal":{"name":"Chemical Industry","volume":"4 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-09-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chemical Industry","FirstCategoryId":"1087","ListUrlMain":"https://doi.org/10.2298/hemind210307024c","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
The main aim of this investigation was an experimental analysis of the air
cleaning efficiency in a mock-up next-generation air cleaning device -
one-level 8-channel industrial cyclone-separator with quarter-rings - while
changing parameters of the inner structure and the assessment of the effects
of dispersion of particulate matter. Therefore, the research was carried out
in two stages: the first stage covered the analysis of the efficiency of the
multi-channel cyclone with particulate matter of <20 and <50 ?m. During the
second stage, a cascade impactor was used to measure the particle collection
efficiency in the multi-channel cyclone by fractions: PM1, PM2.5 and PM10.
Results of the tests with using the cascade impactor were compared to show
changes in the PM composition before and after the multi-channel
cyclone-separator. According to the obtained experimental data, the
one-level 8-channel cyclone-separator collects 70 to 80 % of PM up to 10 ?m
in size, 45 to 60 % of PM up to 2.5 ?m in size and 21 to 25 % of PM up to 1
?m in size.