{"title":"Prefabricated Plug-and-Play Unitized Façade System for Deep Retrofitting: The RenoZEB Case Study","authors":"A. Pracucci, Laura Vandi, S. Magnani, Alessia Baietta, Oscar Casadei, Amaia Uriarte, Michele Vavallo","doi":"10.3390/environsciproc2021011009","DOIUrl":null,"url":null,"abstract":"The retrofitting of the existing building stock is one of the most important goals to be pursued to meet European targets. In this context, the RenoZEB project has developed a modular methodology for the deep retrofitting of buildings, which is enabled by a prefabricated plug-and-play façade that integrates different on-market technologies to achieve nZEB standards. This article reports on the activities conducted in the study and design of the RenoZEB prefabricated envelope system, providing insights on the tests conducted and the results achieved for the façade system, with a specific focus on the use of technology laboratory facilities for real-environment validation, which revealed the system to be in line with the project objectives.","PeriodicalId":11904,"journal":{"name":"Environmental Sciences Proceedings","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-11-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Environmental Sciences Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/environsciproc2021011009","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The retrofitting of the existing building stock is one of the most important goals to be pursued to meet European targets. In this context, the RenoZEB project has developed a modular methodology for the deep retrofitting of buildings, which is enabled by a prefabricated plug-and-play façade that integrates different on-market technologies to achieve nZEB standards. This article reports on the activities conducted in the study and design of the RenoZEB prefabricated envelope system, providing insights on the tests conducted and the results achieved for the façade system, with a specific focus on the use of technology laboratory facilities for real-environment validation, which revealed the system to be in line with the project objectives.