ISO test survey on material influence in dimensional computed tomography

Markus Bartscher, Jens Illemann, Ulrich Neuschaefer-Rube
{"title":"ISO test survey on material influence in dimensional computed tomography","authors":"Markus Bartscher,&nbsp;Jens Illemann,&nbsp;Ulrich Neuschaefer-Rube","doi":"10.1016/j.csndt.2016.04.001","DOIUrl":null,"url":null,"abstract":"<div><p>ISO/TC 213/WG 10 is responsible for creating international standards (series ISO 10360) for the acceptance testing of coordinate measuring systems (CMSs). A current topic is creating a future part of ISO 10360 for CMSs using dimensional computed tomography (CT). The discussion is focussed on how to include material thickness influence in acceptance testing. ISO/TC 213/WG 10 decided to perform an experimental survey to study this topic. This ISO test survey covers several national metrology institutes and manufacturers. Reference standards under study made of aluminium are two step cylinders provided by the National Metrology Institute of Japan (NMIJ), and two hole plates provided by the Physikalisch-Technische Bundesanstalt (PTB), Germany. To check for residual errors of CT-based CMSs, additional reference standards may be measured by participants. This report details results and experiences of the participant PTB. PTB applied scaling reference measurements of a multi-sphere standard and a printed circuit board as additional reference standards, i.e. in addition to hole plate and step cylinder measurements, respectively. Measurements were performed in mid 2015 using the PTB dimensional CT system (Nikon Metrology MCT225). In this contribution, special focus is placed on the interpretation of the results and the consequences of a potential testing regime. This text does not directly describe an existing ISO standard nor a published or intended ISO standard draft. It is intended to contribute to the research of influence parameters which are relevant for a possible future part of ISO 10360 for the case of CT-based CMS (which is assumed to be part 11).</p></div>","PeriodicalId":100221,"journal":{"name":"Case Studies in Nondestructive Testing and Evaluation","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2016-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.csndt.2016.04.001","citationCount":"33","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Case Studies in Nondestructive Testing and Evaluation","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2214657116300065","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 33

Abstract

ISO/TC 213/WG 10 is responsible for creating international standards (series ISO 10360) for the acceptance testing of coordinate measuring systems (CMSs). A current topic is creating a future part of ISO 10360 for CMSs using dimensional computed tomography (CT). The discussion is focussed on how to include material thickness influence in acceptance testing. ISO/TC 213/WG 10 decided to perform an experimental survey to study this topic. This ISO test survey covers several national metrology institutes and manufacturers. Reference standards under study made of aluminium are two step cylinders provided by the National Metrology Institute of Japan (NMIJ), and two hole plates provided by the Physikalisch-Technische Bundesanstalt (PTB), Germany. To check for residual errors of CT-based CMSs, additional reference standards may be measured by participants. This report details results and experiences of the participant PTB. PTB applied scaling reference measurements of a multi-sphere standard and a printed circuit board as additional reference standards, i.e. in addition to hole plate and step cylinder measurements, respectively. Measurements were performed in mid 2015 using the PTB dimensional CT system (Nikon Metrology MCT225). In this contribution, special focus is placed on the interpretation of the results and the consequences of a potential testing regime. This text does not directly describe an existing ISO standard nor a published or intended ISO standard draft. It is intended to contribute to the research of influence parameters which are relevant for a possible future part of ISO 10360 for the case of CT-based CMS (which is assumed to be part 11).

尺寸计算机断层扫描中材料影响的ISO试验调查
ISO/TC 213/WG 10负责制定坐标测量系统(cms)验收测试的国际标准(ISO 10360系列)。当前的一个主题是为使用三维计算机断层扫描(CT)的cms创建ISO 10360的未来部分。重点讨论了如何在验收试验中考虑材料厚度的影响。ISO/TC 213/WG 10决定进行一项实验调查来研究这个主题。这项ISO测试调查涵盖了几个国家计量机构和制造商。正在研究的铝制参考标准是由日本国家计量研究所(NMIJ)提供的两个台阶圆柱体和由德国物理技术委员会(PTB)提供的两个孔板。为了检查基于ct的cms的残差,参与者可以测量额外的参考标准。本报告详细介绍了PTB参与者的结果和经验。PTB分别在孔板和阶梯圆柱测量之外,应用多球面标准和印刷电路板的标度参考测量作为附加参考标准。2015年年中,使用PTB尺寸CT系统(尼康计量MCT225)进行测量。在这篇文章中,特别关注的是对结果的解释和潜在测试制度的后果。本文没有直接描述现有的ISO标准,也没有发布或拟发布的ISO标准草案。它的目的是对影响参数的研究做出贡献,这些参数与ISO 10360基于ct的CMS(假定为第11部分)的可能未来部分相关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信