In vitro evaluation of Doppler pressure gradient

P. Verdonck, R. Verhoeven, A. Kleven
{"title":"In vitro evaluation of Doppler pressure gradient","authors":"P. Verdonck, R. Verhoeven, A. Kleven","doi":"10.1109/CIC.1993.378447","DOIUrl":null,"url":null,"abstract":"Evaluation of prosthetic heart valves using Doppler echocardiography remains still controversial although Doppler technique has become standardized for assessing native heart valve function. One of the reasons is the discrepancy between Doppler and catheter gradient due to pressure recovery. This threshold can be overcome by in vitro standardization effects because both gradients are coupled by /spl Delta/p/sub doppler/=8g/K /spl Delta/p/sub catheter/ with K pressure loss coefficient dependent on prosthetic valve geometry and g gravitational acceleration. The authors try to give some clarification in this matter.<<ETX>>","PeriodicalId":20445,"journal":{"name":"Proceedings of Computers in Cardiology Conference","volume":"15 1","pages":"289-292"},"PeriodicalIF":0.0000,"publicationDate":"1993-09-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of Computers in Cardiology Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CIC.1993.378447","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Evaluation of prosthetic heart valves using Doppler echocardiography remains still controversial although Doppler technique has become standardized for assessing native heart valve function. One of the reasons is the discrepancy between Doppler and catheter gradient due to pressure recovery. This threshold can be overcome by in vitro standardization effects because both gradients are coupled by /spl Delta/p/sub doppler/=8g/K /spl Delta/p/sub catheter/ with K pressure loss coefficient dependent on prosthetic valve geometry and g gravitational acceleration. The authors try to give some clarification in this matter.<>
体外评价多普勒压力梯度
使用多普勒超声心动图评估人工心脏瓣膜仍然存在争议,尽管多普勒技术已经成为评估天然心脏瓣膜功能的标准化技术。其中一个原因是由于压力恢复引起的多普勒和导管梯度的差异。这一阈值可以通过体外标准化效应克服,因为这两个梯度由/spl δ /p/亚多普勒/=8g/K /spl δ /p/亚导管/耦合,K压力损失系数取决于人工瓣膜几何形状和g重力加速度。作者试图对这个问题作一些澄清。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信