{"title":"Development of Interdigitated-Type Planar Capacitive Flex-Sensor Array for the Detection of Damages in Civil Engineering Structures","authors":"Meghayu Adhvaryu, P. Patel, C. Modhera","doi":"10.1166/sl.2020.4240","DOIUrl":null,"url":null,"abstract":"A modified Interdigitated Planar Electrode (IDE) design is presented and used in the development of flex-sensor for Structural Health Monitoring (SHM). The design of IDE consists of a U-shaped electrode with integrated interdigitated electrodes. The overall size of the unit-cell structure\n is 25 × 25 mm2. Different civil engineering blocks were tested using the proposed sensor and a comprehensive crack analysis is presented based on the crack parameters. The sensor offers a lowest average sensitivity of 0.863157 pF/mm. The proposed flex-sensor can also be potentially\n used for the detection and monitoring of other structural parameters like corrosion, moisture content etc.","PeriodicalId":21781,"journal":{"name":"Sensor Letters","volume":"48 1","pages":"389-394"},"PeriodicalIF":0.0000,"publicationDate":"2020-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensor Letters","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1166/sl.2020.4240","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
A modified Interdigitated Planar Electrode (IDE) design is presented and used in the development of flex-sensor for Structural Health Monitoring (SHM). The design of IDE consists of a U-shaped electrode with integrated interdigitated electrodes. The overall size of the unit-cell structure
is 25 × 25 mm2. Different civil engineering blocks were tested using the proposed sensor and a comprehensive crack analysis is presented based on the crack parameters. The sensor offers a lowest average sensitivity of 0.863157 pF/mm. The proposed flex-sensor can also be potentially
used for the detection and monitoring of other structural parameters like corrosion, moisture content etc.
期刊介绍:
The growing interest and activity in the field of sensor technologies requires a forum for rapid dissemination of important results: Sensor Letters is that forum. Sensor Letters offers scientists, engineers and medical experts timely, peer-reviewed research on sensor science and technology of the highest quality. Sensor Letters publish original rapid communications, full papers and timely state-of-the-art reviews encompassing the fundamental and applied research on sensor science and technology in all fields of science, engineering, and medicine. Highest priority will be given to short communications reporting important new scientific and technological findings.