CHANGES IN THE BIOELECTRIC ACTIVITY OF MUSCULUS MASSETER IN CASE OF MANDIBLE EDENTULOUSNESS TREATMENT

B. Pelekhan, M. Rozhko
{"title":"CHANGES IN THE BIOELECTRIC ACTIVITY OF MUSCULUS MASSETER IN CASE OF MANDIBLE EDENTULOUSNESS TREATMENT","authors":"B. Pelekhan, M. Rozhko","doi":"10.21802/artm.2022.4.24.128","DOIUrl":null,"url":null,"abstract":"The objective of the research: to define the dynamics of changes in bioelectric activity of mm. masseter dexter et sinister in patients with mandible edentulousness treated by means of four implant-supported dental prostheses of various types. \n105 patients were examined at the premises of the Center of Dentistry of the University Clinic of Ivano-Frankivsk National Medical University. 30 individuals out of 105 at the age of 23-28 with intact dentition, without somatic pathology were included in the control group. \n75 patients with mandible edentulousness underwent clinical examination, prosthodontic treatment, and follow-up. 3 clinical groups (Group I; II; III) were formed from this cohort of patients depending on the structural features of the manufactured dental prostheses. \nWe conducted electromyography of mm. masseter dexter et sinister to the patients of the examination groups (n = 75) and the control group (n = 30) in order to achieve the objective of the research. The examination was performed by means of two-channel electroneuromyographic complex “Neuro-EMG-Micro” (“Neurosoft”) in the functional diagnostics office at the premises of the Department of Dentistry of Postgraduate Study Faculty at IFNMU. \nQuantitative indicators of bioelectrical activity of the right and left masticatory muscles were analyzed. Namely, the average values of the maximum amplitudes (μV) when performing the test of maximum bite force were analyzed. Recording of electromyographic indicators was performed before the prosthodontic treatment, 14 days after the fixation of the dental prosthesis, in 6 months and 12 months after the dental prosthesis functioning in order to study the dynamics of changes in the indicators of the examination groups. \nElectromyography recording and analysis of the findings in the individuals of the control group was performed once. \nAnalyzing quantitative indicators of electromyographic examination significant differences in the dynamics of an increase in the indicators in 12 months compared to the initial indicators depending on the type of fixed dental prosthesis (subgroup A рІ-ІІІ<0.001; subgroup B рІ-ІІІ<0.001) and the order of prosthodontic treatment (рА-Б <0.001 for all groups of patients) were observed. \n \nDespite the fact that bioelectric indicators of mm. masseter dexter et sinister activity in the patients of the examination groups approximated to the indices of the control group, the dynamics of change was not equivalent and depended on the type of the dental prosthesis. \nThe dynamics of an increase in the indicators of the patients in the examination groups differed by growth, however, the greatest increase was recorded in the period of “14 days” – “6 months” after the fixation of the dental prosthesis. \nOn performing the test of maximum bite, the indicators of the masticatory muscles bioelectrical activity increased during the period named “before the treatment” – “12 months of functioning” most of all in IIIA examination group – by 66.52% (рd<0.001) on the right and by 76.37% (рd<0.001) on the left; and IIIB examination group – by 61.63% (рd<0.001) on the right and 67.20% (рd<0.001) on the left. The lowest indicators have increased in patients of IA examination group – 39.98% (рd<0.001) on the right and 39.95% (рd<0.001) on the left and IB examination group – by 32.48% (рd<0.001) on the right and by 34.75% (рd<0.001) on the left. \n","PeriodicalId":86625,"journal":{"name":"The Glaxo volume; an occasional contribution to the science and art of medicine","volume":"49 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-01-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Glaxo volume; an occasional contribution to the science and art of medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21802/artm.2022.4.24.128","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The objective of the research: to define the dynamics of changes in bioelectric activity of mm. masseter dexter et sinister in patients with mandible edentulousness treated by means of four implant-supported dental prostheses of various types. 105 patients were examined at the premises of the Center of Dentistry of the University Clinic of Ivano-Frankivsk National Medical University. 30 individuals out of 105 at the age of 23-28 with intact dentition, without somatic pathology were included in the control group. 75 patients with mandible edentulousness underwent clinical examination, prosthodontic treatment, and follow-up. 3 clinical groups (Group I; II; III) were formed from this cohort of patients depending on the structural features of the manufactured dental prostheses. We conducted electromyography of mm. masseter dexter et sinister to the patients of the examination groups (n = 75) and the control group (n = 30) in order to achieve the objective of the research. The examination was performed by means of two-channel electroneuromyographic complex “Neuro-EMG-Micro” (“Neurosoft”) in the functional diagnostics office at the premises of the Department of Dentistry of Postgraduate Study Faculty at IFNMU. Quantitative indicators of bioelectrical activity of the right and left masticatory muscles were analyzed. Namely, the average values of the maximum amplitudes (μV) when performing the test of maximum bite force were analyzed. Recording of electromyographic indicators was performed before the prosthodontic treatment, 14 days after the fixation of the dental prosthesis, in 6 months and 12 months after the dental prosthesis functioning in order to study the dynamics of changes in the indicators of the examination groups. Electromyography recording and analysis of the findings in the individuals of the control group was performed once. Analyzing quantitative indicators of electromyographic examination significant differences in the dynamics of an increase in the indicators in 12 months compared to the initial indicators depending on the type of fixed dental prosthesis (subgroup A рІ-ІІІ<0.001; subgroup B рІ-ІІІ<0.001) and the order of prosthodontic treatment (рА-Б <0.001 for all groups of patients) were observed. Despite the fact that bioelectric indicators of mm. masseter dexter et sinister activity in the patients of the examination groups approximated to the indices of the control group, the dynamics of change was not equivalent and depended on the type of the dental prosthesis. The dynamics of an increase in the indicators of the patients in the examination groups differed by growth, however, the greatest increase was recorded in the period of “14 days” – “6 months” after the fixation of the dental prosthesis. On performing the test of maximum bite, the indicators of the masticatory muscles bioelectrical activity increased during the period named “before the treatment” – “12 months of functioning” most of all in IIIA examination group – by 66.52% (рd<0.001) on the right and by 76.37% (рd<0.001) on the left; and IIIB examination group – by 61.63% (рd<0.001) on the right and 67.20% (рd<0.001) on the left. The lowest indicators have increased in patients of IA examination group – 39.98% (рd<0.001) on the right and 39.95% (рd<0.001) on the left and IB examination group – by 32.48% (рd<0.001) on the right and by 34.75% (рd<0.001) on the left.
下颌骨无牙治疗后咬肌生物电活动的变化
研究目的:探讨四种不同类型种植义齿治疗下颌骨无牙患者下颌咬牙侧的生物电活动变化动态。105名患者在伊万诺-弗兰科夫斯克国立医科大学大学诊所牙科中心接受了检查。105名患者中有30名年龄在23-28岁,牙列完整,无躯体病理,被纳入对照组。对75例下颌骨无牙进行临床检查、修复治疗及随访。临床3组(第一组;二世;III)是根据人工修复体的结构特征从这组患者中形成的。为了达到研究目的,我们对检查组(n = 75)和对照组(n = 30)的患者进行了mm.咬肌右侧肌电图。检查是通过双通道神经肌电图复合体“神经肌电-微”(“Neurosoft”)在IFNMU研究生研究学院牙科系的功能诊断办公室进行的。分析左、右咀嚼肌生物电活性定量指标。即对进行最大咬合力试验时的最大幅值(μV)的平均值进行分析。分别在修复治疗前、修复体固定后14天、修复体功能恢复后6个月和12个月记录肌电图指标,研究各检查组各项指标的变化动态。对对照组个体进行一次肌电记录和分析。对肌电图定量指标进行分析,不同固定义齿类型患者12个月内各项指标的增加动态与初始指标的增加动态有显著差异(A亚组рІ-ІІІ<0.001;观察B亚组рІ-ІІІ<0.001)和修复治疗顺序(各组患者рА-Б <0.001)。尽管检查组患者的mm. masseter dexter的生物电指标与对照组的指标接近,但变化的动态并不等同,并且取决于义齿的类型。各检查组患者各项指标的增长动态因生长而异,但在固定义齿后的“14天”-“6个月”期间,各项指标的增长幅度最大。在进行最大咬合测试时,咀嚼肌生物电活动指标在“治疗前”-“功能12个月”期间均有增加,其中以IIIA检查组最多,右侧增加66.52% (d<0.001),左侧增加76.37% (d<0.001);IIIB组,右侧61.63% (p <0.001),左侧67.20% (p <0.001)。IA检查组患者最低指标右侧增加39.98% ( <0.001),左侧增加39.95% ( <0.001), IB检查组右侧增加32.48% ( <0.001),左侧增加34.75% ( <0.001)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信