{"title":"Enhanced sensitivity of Au@Bi2WO6 flower-like materials to formaldehyde","authors":"Ruifeng Zhang,&nbsp;Lei Liu,&nbsp;Weiye Yang,&nbsp;Yao Liu,&nbsp;Yingkai Liu","doi":"10.1186/s11671-023-03923-4","DOIUrl":null,"url":null,"abstract":"<div><p>Bi<sub>2</sub>WO<sub>6</sub> flower-like materials (FMs) were prepared by a hydrothermal method, followed by an in-situ reduction method to prepare Au@Bi<sub>2</sub>WO<sub>6</sub> FMs. X-ray diffraction, scanning electron microscopy, transmission electron microscopy, high-resolution transmission electron microscopy, and X-ray photoelectron spectroscopy were employed to characterize the samples. It was discovered that the calculated O<sub>V</sub> content of Au@Bi<sub>2</sub>WO<sub>6</sub> FMs is 25.16% whereas that of Bi<sub>2</sub>WO<sub>6</sub> FMs is 20.81%, offering appropriate active sites for the absorption of gases and thus enhancing outstanding sensing property. Moreover, the detection of volatile and hazardous substances such as formaldehyde, methanol, acetone, benzene, toluene, and xylene was carried out to assess the efficacy of the Au@Bi<sub>2</sub>WO<sub>6</sub> FMs sensors. The optimal operating temperatures for the Bi<sub>2</sub>WO<sub>6</sub> FMs and Au@Bi<sub>2</sub>WO<sub>6</sub> FMs sensors were 290 and 260 °C, respectively. Compared with Au@Bi<sub>2</sub>WO<sub>6</sub> FMs sensor and Bi<sub>2</sub>WO<sub>6</sub> FMs one, the best response of the front was 250 (900)–100 (800) ppm formaldehyde whereas that of the latter was 90 (230). Therefore, Au@ Bi<sub>2</sub>WO<sub>6</sub> FMs have good response and selectivity, which are promising candidates for formaldehyde detection.</p></div>","PeriodicalId":715,"journal":{"name":"Nanoscale Research Letters","volume":"18 1","pages":""},"PeriodicalIF":4.7030,"publicationDate":"2023-11-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10643700/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nanoscale Research Letters","FirstCategoryId":"88","ListUrlMain":"https://link.springer.com/article/10.1186/s11671-023-03923-4","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Bi2WO6 flower-like materials (FMs) were prepared by a hydrothermal method, followed by an in-situ reduction method to prepare Au@Bi2WO6 FMs. X-ray diffraction, scanning electron microscopy, transmission electron microscopy, high-resolution transmission electron microscopy, and X-ray photoelectron spectroscopy were employed to characterize the samples. It was discovered that the calculated OV content of Au@Bi2WO6 FMs is 25.16% whereas that of Bi2WO6 FMs is 20.81%, offering appropriate active sites for the absorption of gases and thus enhancing outstanding sensing property. Moreover, the detection of volatile and hazardous substances such as formaldehyde, methanol, acetone, benzene, toluene, and xylene was carried out to assess the efficacy of the Au@Bi2WO6 FMs sensors. The optimal operating temperatures for the Bi2WO6 FMs and Au@Bi2WO6 FMs sensors were 290 and 260 °C, respectively. Compared with Au@Bi2WO6 FMs sensor and Bi2WO6 FMs one, the best response of the front was 250 (900)–100 (800) ppm formaldehyde whereas that of the latter was 90 (230). Therefore, Au@ Bi2WO6 FMs have good response and selectivity, which are promising candidates for formaldehyde detection.

Abstract Image

提高Au@Bi2WO6花状材料对甲醛的敏感性。
采用水热法制备Bi2WO6花状材料(FMs),再采用原位还原法制备Au@Bi2WO6花状材料。采用x射线衍射、扫描电镜、透射电镜、高分辨率透射电镜和x射线光电子能谱对样品进行表征。研究发现,Au@Bi2WO6分子式的OV含量为25.16%,而Bi2WO6分子式的OV含量为20.81%,为气体的吸收提供了合适的活性位点,从而提高了优异的传感性能。此外,还对甲醛、甲醇、丙酮、苯、甲苯和二甲苯等挥发性有害物质进行了检测,以评估Au@Bi2WO6 FMs传感器的功效。Bi2WO6 FMs和Au@Bi2WO6 FMs传感器的最佳工作温度分别为290℃和260℃。与Au@Bi2WO6 FMs传感器和Bi2WO6 FMs传感器相比,前者的最佳响应为250 (900)~ 100 (800)ppm甲醛,后者的最佳响应为90 (230)ppm甲醛。因此,Au@ Bi2WO6 FMs具有良好的响应性和选择性,是很有前途的甲醛检测候选材料。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Nanoscale Research Letters
Nanoscale Research Letters NANOSCIENCE & NANOTECHNOLOGY-MATERIALS SCIENCE, MULTIDISCIPLINARY
CiteScore
15.00
自引率
0.00%
发文量
110
审稿时长
2.5 months
期刊介绍: Nanoscale Research Letters (NRL) provides an interdisciplinary forum for communication of scientific and technological advances in the creation and use of objects at the nanometer scale. NRL is the first nanotechnology journal from a major publisher to be published with Open Access.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信