Evaluating the Potential of a New Low-Profile Urinary Catheter in Preventing Catheter-Associated Urinary Tract Infections: A Prospective Randomized Blinded Clinical Trial.

IF 1.5 Q3 HEALTH POLICY & SERVICES
Health Services Research and Managerial Epidemiology Pub Date : 2023-11-09 eCollection Date: 2023-01-01 DOI:10.1177/23333928231211410
Farahnaz Ramezani, Mahnaz Khatiban, Farshid Rahimbashar, Ali Reza Soltanian, Seyed Habibollah Mousavi-Bahar, Ensieh Elyasi
{"title":"Evaluating the Potential of a New Low-Profile Urinary Catheter in Preventing Catheter-Associated Urinary Tract Infections: A Prospective Randomized Blinded Clinical Trial.","authors":"Farahnaz Ramezani, Mahnaz Khatiban, Farshid Rahimbashar, Ali Reza Soltanian, Seyed Habibollah Mousavi-Bahar, Ensieh Elyasi","doi":"10.1177/23333928231211410","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>To investigate the efficacy of a new low-profile catheter on incidence of the catheter-associated urinary tract infections (CAUTI) in comatose patients admitted to the intensive care unit.</p><p><strong>Background: </strong>Catheter-induced urothelial injury is a key component in the development of urinary tract infections in catheterized patients.</p><p><strong>Methods: </strong>In this prospective randomized blinded clinical trial, 80 patients requiring indwelling urinary catheterization were equally randomized to either the standard Foley catheter (control) or the low-profile catheter (experimental) group. The signs of urinary tract infection for comatose patients were considered (ie, ≥10<sup>5</sup> of colony-forming unit/milliliter of urine, hematuria, serum leukocytes, and body temperature) and recorded at baseline and on days 3 and 5 after catheterization. The analysis of covariance was applied by the SPSS-20 software at a 95% confidence level.</p><p><strong>Results: </strong>An increasing proportion of patients with elevated urinary colony counts were seen in the Foley catheter group compared with the low-profile catheter group (12.5% vs 5%). However, there were no between-group differences in the urinary colony counts and body temperature after controlling for antibiotic doses and fluid intake. Patients in the low-profile catheter group had significantly lower rates of hematuria and serum leukocytes than those in the Foley catheter group.</p><p><strong>Conclusion: </strong>A newly designed low-profile urinary catheter has demonstrated a trend toward reducing the incidence of CAUTI in patients with indwelling urinary catheters. Further studies with larger sample sizes and follow-up are needed to confirm the benefits.</p>","PeriodicalId":12951,"journal":{"name":"Health Services Research and Managerial Epidemiology","volume":"10 ","pages":"23333928231211410"},"PeriodicalIF":1.5000,"publicationDate":"2023-11-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10638883/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Health Services Research and Managerial Epidemiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/23333928231211410","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"HEALTH POLICY & SERVICES","Score":null,"Total":0}
引用次数: 0

Abstract

Aim: To investigate the efficacy of a new low-profile catheter on incidence of the catheter-associated urinary tract infections (CAUTI) in comatose patients admitted to the intensive care unit.

Background: Catheter-induced urothelial injury is a key component in the development of urinary tract infections in catheterized patients.

Methods: In this prospective randomized blinded clinical trial, 80 patients requiring indwelling urinary catheterization were equally randomized to either the standard Foley catheter (control) or the low-profile catheter (experimental) group. The signs of urinary tract infection for comatose patients were considered (ie, ≥105 of colony-forming unit/milliliter of urine, hematuria, serum leukocytes, and body temperature) and recorded at baseline and on days 3 and 5 after catheterization. The analysis of covariance was applied by the SPSS-20 software at a 95% confidence level.

Results: An increasing proportion of patients with elevated urinary colony counts were seen in the Foley catheter group compared with the low-profile catheter group (12.5% vs 5%). However, there were no between-group differences in the urinary colony counts and body temperature after controlling for antibiotic doses and fluid intake. Patients in the low-profile catheter group had significantly lower rates of hematuria and serum leukocytes than those in the Foley catheter group.

Conclusion: A newly designed low-profile urinary catheter has demonstrated a trend toward reducing the incidence of CAUTI in patients with indwelling urinary catheters. Further studies with larger sample sizes and follow-up are needed to confirm the benefits.

评估一种新型低姿态导尿管预防导尿管相关尿路感染的潜力:一项前瞻性随机盲法临床试验
目的:探讨新型低姿态导尿管对重症监护病房昏迷患者尿路感染(CAUTI)发生率的影响。背景:导尿诱导的尿路上皮损伤是导尿患者发生尿路感染的关键因素。方法:在本前瞻性随机盲法临床试验中,80例需要留置导尿的患者平均随机分为标准Foley导尿组(对照组)和低规格导尿组(实验组)。考虑昏迷患者的尿路感染征象(如尿、血尿、血清白细胞、体温≥105个菌落形成单位/毫升),并在基线和置管后第3天和第5天记录。协方差分析采用SPSS-20软件,置信水平为95%。结果:与低姿态导尿管组相比,Foley导尿管组尿菌落计数升高的患者比例增加(12.5% vs 5%)。然而,在控制抗生素剂量和液体摄入量后,尿菌落计数和体温在组间没有差异。低姿态导尿管组患者的血尿和血清白细胞率明显低于Foley导尿管组。结论:新设计的低姿态导尿管显示出降低留置导尿管患者CAUTI发生率的趋势。需要更大样本量的进一步研究和随访来证实其益处。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.60
自引率
6.20%
发文量
32
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信