Stress Distribution on Short Implants at Maxillary Posterior Alveolar Bone Model With Different Bone-to-Implant Contact Ratio: Finite Element Analysis.

D. Yazıcıoğlu, B. Bayram, Y. Oğuz, Duygu Çınar, S. Uçkan
{"title":"Stress Distribution on Short Implants at Maxillary Posterior Alveolar Bone Model With Different Bone-to-Implant Contact Ratio: Finite Element Analysis.","authors":"D. Yazıcıoğlu, B. Bayram, Y. Oğuz, Duygu Çınar, S. Uçkan","doi":"10.1563/aaid-doi-D-14-00003","DOIUrl":null,"url":null,"abstract":"The aim of this study was to evaluate the stress distribution of the short dental implants and bone-to-implant contact ratios in the posterior maxilla using 3-dimensional (3D) finite element models. Two different 3D maxillary posterior bone segments were modeled. Group 1 was composed of a bone segment consisting of cortical bone and type IV cancellous bone with 100% bone-to-implant contact. Group 2 was composed of a bone segment consisting of cortical bone and type IV cancellous bone including spherical bone design and homogenous tubular hollow spaced structures with 30% spherical porosities and 70% bone-to-implant contact ratio. Four-millimeter-diameter and 5-mm-height dental implants were assumed to be osseointegrated and placed at the center of the segments. Lateral occlusal bite force (300 N) was applied at a 25° inclination to the implants long axis. The maximum von Mises stresses in cortical and cancellous bones and implant-abutment complex were calculated. The von Mises stress values on the implants and the cancellous bone around the implants of the 70% bone-to-implant contact group were almost 3 times higher compared with the values of the 100% bone-to-implant contact group. For clinical reality, use of the 70% model for finite element analysis simulation of the posterior maxilla region better represents real alveolar bone and the increased stress and strain distributions evaluated on the cortical and cancellous bone around the dental implants.","PeriodicalId":77634,"journal":{"name":"The International journal of oral implantology : implantologist","volume":"37 1","pages":"26-33"},"PeriodicalIF":0.0000,"publicationDate":"2016-02-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The International journal of oral implantology : implantologist","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1563/aaid-doi-D-14-00003","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17

Abstract

The aim of this study was to evaluate the stress distribution of the short dental implants and bone-to-implant contact ratios in the posterior maxilla using 3-dimensional (3D) finite element models. Two different 3D maxillary posterior bone segments were modeled. Group 1 was composed of a bone segment consisting of cortical bone and type IV cancellous bone with 100% bone-to-implant contact. Group 2 was composed of a bone segment consisting of cortical bone and type IV cancellous bone including spherical bone design and homogenous tubular hollow spaced structures with 30% spherical porosities and 70% bone-to-implant contact ratio. Four-millimeter-diameter and 5-mm-height dental implants were assumed to be osseointegrated and placed at the center of the segments. Lateral occlusal bite force (300 N) was applied at a 25° inclination to the implants long axis. The maximum von Mises stresses in cortical and cancellous bones and implant-abutment complex were calculated. The von Mises stress values on the implants and the cancellous bone around the implants of the 70% bone-to-implant contact group were almost 3 times higher compared with the values of the 100% bone-to-implant contact group. For clinical reality, use of the 70% model for finite element analysis simulation of the posterior maxilla region better represents real alveolar bone and the increased stress and strain distributions evaluated on the cortical and cancellous bone around the dental implants.
不同骨-种植体接触比下上颌后牙槽骨模型短种植体的应力分布:有限元分析
本研究的目的是利用三维有限元模型评估短牙种植体的应力分布和后上颌骨与种植体的接触比。对两个不同的上颌后骨段进行三维建模。第1组骨段由骨与种植体100%接触的皮质骨和IV型松质骨组成。2组骨段由皮质骨和IV型松质骨组成,包括球形骨设计和均匀管状空心间隔结构,球形孔隙率为30%,骨与种植体接触比为70%。直径为4毫米,高度为5毫米的种植体被认为是骨整合的,并放置在节段的中心。在种植体长轴倾斜25°处施加侧向咬合力(300 N)。计算了皮质骨、松质骨和种植-基牙复合体的最大von Mises应力。70%骨-种植体接触组种植体和种植体周围松质骨的von Mises应力值比100%骨-种植体接触组高近3倍。从临床实际出发,采用70%模型对上颌骨后区进行有限元分析模拟,可以更好地反映真实的牙槽骨,并对种植体周围皮质骨和松质骨的应力应变分布进行评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书