Elbow joint angle dependency of biceps brachii muscle stiffness with an aid of system identification of mechanomyogram

Q4 Engineering
Y. Itabashi, T. Uchiyama
{"title":"Elbow joint angle dependency of biceps brachii muscle stiffness with an aid of system identification of mechanomyogram","authors":"Y. Itabashi, T. Uchiyama","doi":"10.11239/jsmbe.52.O-164","DOIUrl":null,"url":null,"abstract":"The purpose of this study is to investigate the relation between stiffness and the elbow joint angle. A mechanomyogram (MMG) was recorded from biceps brachii muscle at three different elbow angles: 90, 120, and 150 degrees. The biceps brachii muscle was electrically stimulated and its mechanomyogram was measured with an acceleration sensor attached to the skin of the belly of the biceps brachii muscle. The transfer functions from the stimulation to the MMG were identified by the singular value decomposition method, and the natural frequency was derived from the transfer function. As a result, the MMG was approximated with a fourth-order model. The lowest natural frequency increased as the elbow joint angle increased. It was concluded that biceps brachii muscle stiffness increased as the elbow joint angle increased.","PeriodicalId":39233,"journal":{"name":"Transactions of Japanese Society for Medical and Biological Engineering","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2014-08-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Transactions of Japanese Society for Medical and Biological Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11239/jsmbe.52.O-164","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0

Abstract

The purpose of this study is to investigate the relation between stiffness and the elbow joint angle. A mechanomyogram (MMG) was recorded from biceps brachii muscle at three different elbow angles: 90, 120, and 150 degrees. The biceps brachii muscle was electrically stimulated and its mechanomyogram was measured with an acceleration sensor attached to the skin of the belly of the biceps brachii muscle. The transfer functions from the stimulation to the MMG were identified by the singular value decomposition method, and the natural frequency was derived from the transfer function. As a result, the MMG was approximated with a fourth-order model. The lowest natural frequency increased as the elbow joint angle increased. It was concluded that biceps brachii muscle stiffness increased as the elbow joint angle increased.
借助机械肌图系统识别肘关节角度对肱二头肌僵硬度的影响
本研究的目的是探讨刚度与肘关节角度的关系。在三个不同的肘关节角度:90度、120度和150度时,记录肱二头肌的肌力图(MMG)。对肱二头肌进行电刺激,并用附着在肱二头肌腹部皮肤上的加速度传感器测量其机械肌图。采用奇异值分解方法识别了从刺激到MMG的传递函数,并由传递函数导出了固有频率。因此,用四阶模型逼近了MMG。最低固有频率随肘关节角度的增大而增大。结论:肱二头肌僵硬度随肘关节角度的增加而增加。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.10
自引率
0.00%
发文量
0
文献相关原料
公司名称 产品信息 采购帮参考价格
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信