Confiabilidade da versão brasileira do Wolf Motor Function Test em adultos com hemiparesia

Natalia Duarte Pereira, S. M. Michaelsen, Isabella S. Menezes, A. Ovando, R. Lima, Luci Fuscaldi Teixeira-Salmela
{"title":"Confiabilidade da versão brasileira do Wolf Motor Function Test em adultos com hemiparesia","authors":"Natalia Duarte Pereira, S. M. Michaelsen, Isabella S. Menezes, A. Ovando, R. Lima, Luci Fuscaldi Teixeira-Salmela","doi":"10.1590/S1413-35552011000300013","DOIUrl":null,"url":null,"abstract":"BACKGROUND: The Wolf Motor Function Test (WMFT) evaluates the upper limb (UL) performance of adults with hemiparesis by combining time and quality of movement measures in both isolated movements and functional tasks. OBJECTIVES: To translate and adapt the WMFT form, functional ability scale (FAS) and manual to Brazilian Portuguese and evaluate the intra and inter-rater reliabilities. METHODS: Fifteen individuals with a mean age of 57.9±11.1 years and a mean time since stroke onset of 68.5±53.5 months participated. The WMFT was administered by one physiotherapist based on information in the manual, and video observations were assessed by two other independent physical therapists. Information regarding compensatory movements was included in the FAS. Intra-class correlation coefficients (ICCs) and Bland-Altman plots were calculated to examine the intra- and inter-rater reliabilities for performance time and FAS, whereas weighted kappa (Kp) was used to examine the agreement strength for FAS. RESULTS: The inter-rater ICC values for performance time were above 0.75 in 13 of the 15 tasks. For the FAS, they ranged from 0.87-0.99 for all evaluated tasks, with Kp values ranging from 0.63-0.92. For intra-rater reliability, the ICC ranged from 0.99-1.0 and from 0.96-1.0 for time measurement and FAS, respectively. Kp values ranged from 0.79-0.96 for individual and 0.93 for total scores. CONCLUSION: The Brazilian version of the WMFT showed adequate intra- and inter-rater reliabilities for evaluating the paretic UL of individuals with stroke.","PeriodicalId":21195,"journal":{"name":"Revista Brasileira De Fisioterapia","volume":"21 1","pages":"257-265"},"PeriodicalIF":0.0000,"publicationDate":"2011-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"36","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista Brasileira De Fisioterapia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1590/S1413-35552011000300013","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 36

Abstract

BACKGROUND: The Wolf Motor Function Test (WMFT) evaluates the upper limb (UL) performance of adults with hemiparesis by combining time and quality of movement measures in both isolated movements and functional tasks. OBJECTIVES: To translate and adapt the WMFT form, functional ability scale (FAS) and manual to Brazilian Portuguese and evaluate the intra and inter-rater reliabilities. METHODS: Fifteen individuals with a mean age of 57.9±11.1 years and a mean time since stroke onset of 68.5±53.5 months participated. The WMFT was administered by one physiotherapist based on information in the manual, and video observations were assessed by two other independent physical therapists. Information regarding compensatory movements was included in the FAS. Intra-class correlation coefficients (ICCs) and Bland-Altman plots were calculated to examine the intra- and inter-rater reliabilities for performance time and FAS, whereas weighted kappa (Kp) was used to examine the agreement strength for FAS. RESULTS: The inter-rater ICC values for performance time were above 0.75 in 13 of the 15 tasks. For the FAS, they ranged from 0.87-0.99 for all evaluated tasks, with Kp values ranging from 0.63-0.92. For intra-rater reliability, the ICC ranged from 0.99-1.0 and from 0.96-1.0 for time measurement and FAS, respectively. Kp values ranged from 0.79-0.96 for individual and 0.93 for total scores. CONCLUSION: The Brazilian version of the WMFT showed adequate intra- and inter-rater reliabilities for evaluating the paretic UL of individuals with stroke.
巴西版成人偏瘫沃尔夫运动功能测试的可靠性
背景:Wolf运动功能测试(WMFT)通过在孤立运动和功能性任务中结合运动测量的时间和质量来评估成人偏瘫患者的上肢(UL)表现。目的:将WMFT表格、功能能力量表(FAS)和手册翻译和改编为巴西葡萄牙语,并评估量表内和量表间的信度。方法:15例平均年龄57.9±11.1岁,平均中风发病时间68.5±53.5个月。WMFT由一名物理治疗师根据手册中的信息进行管理,视频观察由另外两名独立的物理治疗师进行评估。关于代偿运动的资料已列入FAS。计算类内相关系数(ICCs)和Bland-Altman图来检验表现时间和FAS的组内和组间信度,而加权kappa (Kp)用于检验FAS的一致性强度。结果:15个任务中有13个任务的工作时间的评分者间ICC值在0.75以上。对于FAS,所有评估任务的Kp值在0.87-0.99之间,Kp值在0.63-0.92之间。对于内部信度,时间测量和FAS的ICC分别在0.99-1.0和0.96-1.0之间。个体Kp值为0.79-0.96,总分Kp值为0.93。结论:巴西版的WMFT在评估脑卒中患者的父母性UL方面显示出足够的内部和内部信度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信