{"title":"PET/CT DISADVANTAGES IN PATIENTS WITH LYMPHOMA: А LITERATURE REVIEW","authors":"F. Bayembaev, R. Rakhimzhanova, T. Dautov, A. Saduakasova, A. Temirbekov","doi":"10.52532/2521-6414-2023-1-67-62-67","DOIUrl":null,"url":null,"abstract":"Relevance: Positron emission tomography combined with computed tomography (PET/CT) is a young and promising technique for lymphoproliferative diseases’ primary detection, staging, and evaluation of the treatment results. However, at this stage of nuclear medicine development, some shortcomings in PET/CT diagnostics of lymphomas using 18Fluorodeoxyglucose (F18-FDG) affect its reliability to a certain extent. \nThe study aimed to evaluate the physical and technical weaknesses of F18-FDG PET/CT in diagnosing lymphomas and review the analytical methods that affect opinion accuracy. \nMethods: The articles on the use of F18-FDG PET/CT in diagnosing lymphomas, its reliability, and methods for optimizing were searched in the PUBMED database for 2012-2022. \nResults: One of the main shortcomings of F18-FDG PET/CT in diagnosing lymphomas is the Deauville 5-point scale, which does not fully meet clinical requirements. This scale has some disadvantages, including low inter-reader agreement and an unreliable reference organ for F18-FDG accumulation. Mathematical algorithms for correction to the patient’s weight also require optimization. \nConclusion: Some of the existing deficiencies can be improved at the software level and through educating staff about the importance of changing the SUV calculation method. However, other deficiencies, such as classifications that do not meet clinical requirements, require more efforts at the level of international experts and much more in-depth study of this issue to avoid such shortcomings of new staging methods. However, even considering all the shortcomings described, at the moment, PET/CT with F18-FDG is one of the most reliable modalities available, both for the initial detection and for evaluating the therapy effectiveness in patients with lymphomas.","PeriodicalId":19480,"journal":{"name":"Oncologia i radiologia Kazakhstana","volume":"31 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-03-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Oncologia i radiologia Kazakhstana","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52532/2521-6414-2023-1-67-62-67","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Relevance: Positron emission tomography combined with computed tomography (PET/CT) is a young and promising technique for lymphoproliferative diseases’ primary detection, staging, and evaluation of the treatment results. However, at this stage of nuclear medicine development, some shortcomings in PET/CT diagnostics of lymphomas using 18Fluorodeoxyglucose (F18-FDG) affect its reliability to a certain extent. The study aimed to evaluate the physical and technical weaknesses of F18-FDG PET/CT in diagnosing lymphomas and review the analytical methods that affect opinion accuracy. Methods: The articles on the use of F18-FDG PET/CT in diagnosing lymphomas, its reliability, and methods for optimizing were searched in the PUBMED database for 2012-2022. Results: One of the main shortcomings of F18-FDG PET/CT in diagnosing lymphomas is the Deauville 5-point scale, which does not fully meet clinical requirements. This scale has some disadvantages, including low inter-reader agreement and an unreliable reference organ for F18-FDG accumulation. Mathematical algorithms for correction to the patient’s weight also require optimization. Conclusion: Some of the existing deficiencies can be improved at the software level and through educating staff about the importance of changing the SUV calculation method. However, other deficiencies, such as classifications that do not meet clinical requirements, require more efforts at the level of international experts and much more in-depth study of this issue to avoid such shortcomings of new staging methods. However, even considering all the shortcomings described, at the moment, PET/CT with F18-FDG is one of the most reliable modalities available, both for the initial detection and for evaluating the therapy effectiveness in patients with lymphomas.
Pet / ct在淋巴瘤患者中的劣势:А文献综述
相关性:正电子发射断层扫描联合计算机断层扫描(PET/CT)是一种年轻而有前途的淋巴增生性疾病的初步检测、分期和治疗结果评估技术。然而,在核医学发展的现阶段,18-氟脱氧葡萄糖(F18-FDG)在PET/CT诊断淋巴瘤方面存在一些不足,在一定程度上影响了其可靠性。本研究旨在评估F18-FDG PET/CT在诊断淋巴瘤方面的物理和技术弱点,并回顾影响诊断准确性的分析方法。方法:检索PUBMED数据库2012-2022年关于F18-FDG PET/CT诊断淋巴瘤、可靠性及优化方法的文章。结果:F18-FDG PET/CT诊断淋巴瘤的主要缺点之一是采用多维尔5分量表,不能完全满足临床要求。该量表有一些缺点,包括阅读器间一致性低,F18-FDG积累的参考机构不可靠。校正病人体重的数学算法也需要优化。结论:现有的一些不足可以在软件层面进行改进,并通过教育员工改变SUV计算方法的重要性。然而,其他的不足,如分类不符合临床要求,需要更多的国际专家的努力和更深入的研究这个问题,以避免新的分期方法的这些缺点。然而,即使考虑到所描述的所有缺点,目前,PET/CT与F18-FDG是最可靠的方式之一,无论是用于淋巴瘤患者的初始检测还是评估治疗效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信