Microcirculation Associated with Degenerative Rotator Cuff Lesions: In Vivo Assessment with Orthogonal Polarization Spectral Imaging During Arthroscopy of the Shoulder

P. Biberthaler, E. Wiedemann, A. Nerlich, M. Kettler, T. Mussack, S. Deckelmann, W. Mutschler
{"title":"Microcirculation Associated with Degenerative Rotator Cuff Lesions: In Vivo Assessment with Orthogonal Polarization Spectral Imaging During Arthroscopy of the Shoulder","authors":"P. Biberthaler, E. Wiedemann, A. Nerlich, M. Kettler, T. Mussack, S. Deckelmann, W. Mutschler","doi":"10.2106/00004623-200303000-00012","DOIUrl":null,"url":null,"abstract":"Background: Diminished vascular supply is associated with degenerative rotator cuff lesions. Orthogonal polarization spectral imaging allows noninvasive assessment of microcirculation without application of fluorescent contrast medium. The aim of our study was to visualize and quantify in vivo the microcirculation of the rotator cuff during arthroscopic surgery and to compare the results with the number of microvessels identified in vitro by immunostaining of biopsy specimens taken from the scanned areas. Methods: Eleven patients with clinical signs of a degenerative rotator cuff lesion were studied. Prior to arthroscopic subacromial decompression, the superficial part of the supraspinatus tendon at the edge of the lesion as well as the unaffected tendon insertion was examined. Microvascular parameters established for the description of tissue perfusion with use of conventional intravital fluorescence microscopy (functional capillary density and capillary diameter) were assessed in vivo. Biopsy specimens were taken from the scanned areas, and the microvessels were localized by immunostaining for the endothelial surface marker CD31. Results: In the region of the unaffected tendon insertion, the mean baseline functional capillary density (and standard deviation) was 106 ± 13 cm/cm 2 and the mean capillary diameter was 10 ± 0.7 &mgr;m. In contrast, at the edge of the lesion, the functional capillary density was significantly reduced to 20 ± 14 cm/cm 2, whereas the diameter of the vessels that were present did not differ. The total number of vessels stained in vitro was also significantly reduced at the edge of the lesion compared with the number of vessels in the tendon insertion zone. Conclusions: Quantitative in vivo analysis of human microcirculation during arthroscopy demonstrated that the functional capillary density at the edge of a degenerative rotator cuff lesion was significantly reduced compared with that in the control tissue. The capacity to assess microcirculatory flow in vivo may help to identify specific repair strategies based on knowledge of individual perfusion patterns.","PeriodicalId":22625,"journal":{"name":"The Journal of Bone & Joint Surgery","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2003-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"105","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of Bone & Joint Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2106/00004623-200303000-00012","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 105

Abstract

Background: Diminished vascular supply is associated with degenerative rotator cuff lesions. Orthogonal polarization spectral imaging allows noninvasive assessment of microcirculation without application of fluorescent contrast medium. The aim of our study was to visualize and quantify in vivo the microcirculation of the rotator cuff during arthroscopic surgery and to compare the results with the number of microvessels identified in vitro by immunostaining of biopsy specimens taken from the scanned areas. Methods: Eleven patients with clinical signs of a degenerative rotator cuff lesion were studied. Prior to arthroscopic subacromial decompression, the superficial part of the supraspinatus tendon at the edge of the lesion as well as the unaffected tendon insertion was examined. Microvascular parameters established for the description of tissue perfusion with use of conventional intravital fluorescence microscopy (functional capillary density and capillary diameter) were assessed in vivo. Biopsy specimens were taken from the scanned areas, and the microvessels were localized by immunostaining for the endothelial surface marker CD31. Results: In the region of the unaffected tendon insertion, the mean baseline functional capillary density (and standard deviation) was 106 ± 13 cm/cm 2 and the mean capillary diameter was 10 ± 0.7 &mgr;m. In contrast, at the edge of the lesion, the functional capillary density was significantly reduced to 20 ± 14 cm/cm 2, whereas the diameter of the vessels that were present did not differ. The total number of vessels stained in vitro was also significantly reduced at the edge of the lesion compared with the number of vessels in the tendon insertion zone. Conclusions: Quantitative in vivo analysis of human microcirculation during arthroscopy demonstrated that the functional capillary density at the edge of a degenerative rotator cuff lesion was significantly reduced compared with that in the control tissue. The capacity to assess microcirculatory flow in vivo may help to identify specific repair strategies based on knowledge of individual perfusion patterns.
与退行性肩袖病变相关的微循环:肩关节镜下正交偏振光谱成像的体内评估
背景:血管供应减少与退行性肩袖病变有关。正交偏振光谱成像允许无创评估微循环不应用荧光造影剂。我们研究的目的是在关节镜手术中观察和量化体内旋转袖的微循环,并将结果与体外通过扫描区域活检标本的免疫染色鉴定的微血管数量进行比较。方法:对11例有退行性肩袖病变临床表现的患者进行分析。在关节镜下肩峰下减压之前,检查病变边缘冈上肌腱的浅表部分以及未受影响的肌腱止点。利用常规活体荧光显微镜建立的用于描述组织灌注的微血管参数(功能毛细血管密度和毛细血管直径)在体内进行评估。从扫描区域取活检标本,内皮表面标记物CD31免疫染色定位微血管。结果:在未受影响的肌腱止点区域,平均基线功能毛细血管密度(和标准差)为106±13 cm/ cm2,平均毛细血管直径为10±0.7 m。相比之下,在病变边缘,功能毛细血管密度显著降低至20±14 cm/ cm2,而存在的血管直径没有差异。与肌腱止点区相比,病变边缘的体外染色血管总数也明显减少。结论:关节镜下人体微循环的定量体内分析表明,与对照组织相比,退行性肩袖病变边缘的功能性毛细血管密度显著降低。评估体内微循环流量的能力可能有助于确定基于个体灌注模式知识的特定修复策略。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信