{"title":"Seismic Performances of Brick Masonry Inverted Bell-shaped Chedi","authors":"Chayanon Hansapinyo","doi":"10.1016/j.apcbee.2014.01.039","DOIUrl":null,"url":null,"abstract":"<div><p>This research is aimed to perform seismic evaluation of an esteemed brick masonry inverted bell-shaped chedi at Phrathat Doi Suthep temple, Chiangmai, Thailand, by using the finite element analysis. The validated finite element model has been made through the full-scale ambient vibration tests (presented in the accompanied paper). First, twenty past earthquake records were selected and matching of the records to the seismic response spectrum was made for equating the local seismic conditions. Then, the matched seismic waves were used for the input of time history analyses. The results have shown that, the top of the pagoda was very sensitive to the seismic waves. It was deformed significantly, accelerations were amplified and the material was damaged by over-tensioning.</p></div>","PeriodicalId":8107,"journal":{"name":"APCBEE Procedia","volume":"9 ","pages":"Pages 217-221"},"PeriodicalIF":0.0000,"publicationDate":"2014-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.apcbee.2014.01.039","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"APCBEE Procedia","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2212670814000402","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6
Abstract
This research is aimed to perform seismic evaluation of an esteemed brick masonry inverted bell-shaped chedi at Phrathat Doi Suthep temple, Chiangmai, Thailand, by using the finite element analysis. The validated finite element model has been made through the full-scale ambient vibration tests (presented in the accompanied paper). First, twenty past earthquake records were selected and matching of the records to the seismic response spectrum was made for equating the local seismic conditions. Then, the matched seismic waves were used for the input of time history analyses. The results have shown that, the top of the pagoda was very sensitive to the seismic waves. It was deformed significantly, accelerations were amplified and the material was damaged by over-tensioning.
本研究的目的是通过有限元分析对泰国清迈素贴寺(Phrathat Doi Suthep temple)一座受人尊敬的砖砌体倒钟形佛塔进行地震评估。通过全尺寸环境振动试验(见附文)建立了验证的有限元模型。首先,选取20次地震记录,与地震反应谱进行匹配,拟合当地地震条件;然后,将匹配的地震波作为时程分析的输入。结果表明,塔顶对地震波非常敏感。它变形明显,加速度被放大,材料因过度张拉而损坏。