Surface Management in Prevention of Nosocomial Infections in Radiography Practice

Nsofor I. Ifeoma Okafor H. Chioma, Okon E. Ime
{"title":"Surface Management in Prevention of Nosocomial Infections in Radiography Practice","authors":"Nsofor I. Ifeoma Okafor H. Chioma, Okon E. Ime","doi":"10.48153/jrrs.v29i1.227065","DOIUrl":null,"url":null,"abstract":"Background: For prevention of nosocomial infections in Radiography practice, it is imperative to disinfect surfaces used by all patients with appropriate disinfectants.Objective: To determine the disinfectants that are most active in eliminating micro-organisms identified on hard surfaces of equipment and accessories in the radiology department of a tertiary hospital. Methodology: Efficacy of Savlon (chlorohexidine), Jik (Sodium hydrochlorite), and Dettol (Chloroxylenol) were tested. Each examined surface was divided into three horizontal parts. Three BS medichem swabs were moistened with distilled water and used to collect sample along each surface at different points. The surfaces were cleaned with each undiluted disinfectant and allowed to dry for 20 minutes. Three different moistened swabs were used to collect another fresh sample. Chocolate agar was used to prepare the samples and later incubated in incumaxTM incubator for 24 hours at 370C. Colonies were identified under national light microscope.Results: Colony count before disinfection was one 150. After cleaning, it reduced to 60. The isolated organisms were: Staphycoccus aureus, Candida albicans, Pseudomonas aeruginosa coliform and Escherichia coli. Staphylococcus aureus which had the highest colony count of 51 before disinfection was reduced to 14 after disinfection. Escherichia coli had the least colony count before and after disinfection. Jik (sodium hydrochlorite) reduced the total bacterial load form 51 to 14 counts.Conclusion: Sodium hypochlorite (Jik) is the most effective disinfectant noticed in our centre.","PeriodicalId":16919,"journal":{"name":"Journal of Radiography and Radiation Sciences","volume":"12 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-06-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Radiography and Radiation Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.48153/jrrs.v29i1.227065","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: For prevention of nosocomial infections in Radiography practice, it is imperative to disinfect surfaces used by all patients with appropriate disinfectants.Objective: To determine the disinfectants that are most active in eliminating micro-organisms identified on hard surfaces of equipment and accessories in the radiology department of a tertiary hospital. Methodology: Efficacy of Savlon (chlorohexidine), Jik (Sodium hydrochlorite), and Dettol (Chloroxylenol) were tested. Each examined surface was divided into three horizontal parts. Three BS medichem swabs were moistened with distilled water and used to collect sample along each surface at different points. The surfaces were cleaned with each undiluted disinfectant and allowed to dry for 20 minutes. Three different moistened swabs were used to collect another fresh sample. Chocolate agar was used to prepare the samples and later incubated in incumaxTM incubator for 24 hours at 370C. Colonies were identified under national light microscope.Results: Colony count before disinfection was one 150. After cleaning, it reduced to 60. The isolated organisms were: Staphycoccus aureus, Candida albicans, Pseudomonas aeruginosa coliform and Escherichia coli. Staphylococcus aureus which had the highest colony count of 51 before disinfection was reduced to 14 after disinfection. Escherichia coli had the least colony count before and after disinfection. Jik (sodium hydrochlorite) reduced the total bacterial load form 51 to 14 counts.Conclusion: Sodium hypochlorite (Jik) is the most effective disinfectant noticed in our centre.
放射线照相术中预防医院感染的表面管理
背景:为了预防医院感染,必须对所有患者使用的表面使用适当的消毒剂进行消毒。目的:确定某三级医院放射科对设备及附件硬表面微生物杀灭效果最好的消毒剂。方法学:考察沙夫隆(氯己定)、吉克(盐酸钠)、德特尔(氯二醇)的药效。每个被检测的表面被分成三个水平部分。用蒸馏水湿润三根BS医学拭子,沿每个表面不同点采集样本。用每种未稀释的消毒剂清洗表面,并让其干燥20分钟。使用三种不同的湿拭子收集另一种新鲜样本。用巧克力琼脂制备样品,于incumaxTM培养箱中370℃孵育24小时。在国家光学显微镜下鉴定菌落。结果:消毒前菌落计数为1 150。清洗后,降至60。分离得到的微生物有:金黄色葡萄球菌、白色念珠菌、铜绿假单胞菌大肠菌和大肠杆菌。金黄色葡萄球菌在消毒前菌落数最高,为51个,消毒后菌落数降至14个。消毒前后大肠杆菌菌落数最少。Jik(氢氯酸钠)将细菌总数从51个减少到14个。结论:次氯酸钠(Jik)是本中心监测到的最有效的消毒剂。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信