{"title":"The study of BeiDou timing receiver delay calibration","authors":"Hongbo Wang, Hang Yi, Shengkang Zhang, Haifeng Wang, F. Shi, Huaiying Shang, Yujie Yang, J. Ge, Zhiqi Li","doi":"10.1109/FCS.2015.7138902","DOIUrl":null,"url":null,"abstract":"This paper gives a test method of BeiDou timing receiver delay. A BeiDou System simulator and a time interval counter were used in the experiments. During the process, the most important step is to calibrate the delay of the simulator. The uncertainty of this method is analyzed to be less than 1.5ns. Using this method, some typical Chinese commercial timing receivers were tested, and the results are shown in figures. The receiver delay variations with temperature have been studied.","PeriodicalId":57667,"journal":{"name":"时间频率公报","volume":"8 1","pages":"541-544"},"PeriodicalIF":0.0000,"publicationDate":"2015-04-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"时间频率公报","FirstCategoryId":"1089","ListUrlMain":"https://doi.org/10.1109/FCS.2015.7138902","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

This paper gives a test method of BeiDou timing receiver delay. A BeiDou System simulator and a time interval counter were used in the experiments. During the process, the most important step is to calibrate the delay of the simulator. The uncertainty of this method is analyzed to be less than 1.5ns. Using this method, some typical Chinese commercial timing receivers were tested, and the results are shown in figures. The receiver delay variations with temperature have been studied.
北斗授时接收机时延标定研究
给出了一种北斗授时接收机时延的测试方法。实验采用了北斗系统模拟器和时间间隔计数器。在此过程中,最重要的一步是对模拟器的延迟进行标定。经分析,该方法的不确定度小于1.5ns。利用该方法对我国典型商用授时接收机进行了测试,测试结果如图所示。研究了接收机时延随温度的变化规律。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
1135
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信