High voltage insulator mechanical load limitations and load resistance factor design

A. Baker
{"title":"High voltage insulator mechanical load limitations and load resistance factor design","authors":"A. Baker","doi":"10.1109/TDC.2012.6281416","DOIUrl":null,"url":null,"abstract":"This paper discusses the current practice for selecting high voltage insulators and the changes needed to accommodate Load Resistance Factor Design. Conversion of insulator rated strength, defined according to ANSI C29 Standards, to damage limit strength to provide the service limit resistance required by LRFD is discussed. Specific values of service limit resistance and strength factors for different types of high voltage insulators are presented for further consideration by those responsible for revising current line loading and strength regulations and insulator standards.","PeriodicalId":19873,"journal":{"name":"PES T&D 2012","volume":"19 1","pages":"1-6"},"PeriodicalIF":0.0000,"publicationDate":"2012-05-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"PES T&D 2012","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TDC.2012.6281416","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This paper discusses the current practice for selecting high voltage insulators and the changes needed to accommodate Load Resistance Factor Design. Conversion of insulator rated strength, defined according to ANSI C29 Standards, to damage limit strength to provide the service limit resistance required by LRFD is discussed. Specific values of service limit resistance and strength factors for different types of high voltage insulators are presented for further consideration by those responsible for revising current line loading and strength regulations and insulator standards.
高压绝缘子机械负载限制及负载阻力系数设计
本文讨论了目前选择高压绝缘子的做法以及为适应负载电阻系数设计所需要的改变。讨论了根据ANSI C29标准定义的绝缘子额定强度转换为提供LRFD所需的使用极限电阻的破坏极限强度。提出了不同类型高压绝缘子的使用极限电阻和强度系数的具体值,供负责修订现行线路负荷和强度规定及绝缘子标准的人员进一步考虑。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信