Damien T. Newcombe, Terence J. Cardwell, Robert W. Cattrall, Spas D. Kolev
{"title":"An optical membrane redox chemical sensor for the determination of ascorbic acid","authors":"Damien T. Newcombe, Terence J. Cardwell, Robert W. Cattrall, Spas D. Kolev","doi":"10.1002/1098-2728(2000)12:4<200::AID-LRA5>3.0.CO;2-2","DOIUrl":null,"url":null,"abstract":"<p>The redox indicator, ferroin, tris(1,10-phenanthroline)iron(II) was incorporated into the perfluorosulfonated cation-exchange membrane Nafion and, together with optical fibers, a photodiode, and a light-emitting diode, was used for the construction of a redox optical sensor (optode). The optode was incorporated in the flow-through cell of a computer-controlled sequential injection (SI) system and used for the determination of ascorbic acid (vitamin C). A linear relationship between the logarithm of the ascorbic acid concentration and the membrane absorbance was obtained for the concentration range from 2.50 × 10<sup>−3</sup> to 1.00 × 10<sup>−1</sup> mol L<sup>−1</sup> and a sample frequency of 17 h<sup>−1</sup>. The concentration of ascorbic acid determined in a number of commercial pharmaceutical products agreed well with iodometric titration results. This result shows that the SI system incorporating the ferroin/Nafion optode is suitable for the automated analysis of ascorbic acid in pharmaceutical products. © 2000 John Wiley & Sons, Inc. Lab Robotics and Automation 12:200–204, 2000</p>","PeriodicalId":100863,"journal":{"name":"Laboratory Robotics and Automation","volume":"12 4","pages":"200-204"},"PeriodicalIF":0.0000,"publicationDate":"2000-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/1098-2728(2000)12:4<200::AID-LRA5>3.0.CO;2-2","citationCount":"11","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Laboratory Robotics and Automation","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/1098-2728%282000%2912%3A4%3C200%3A%3AAID-LRA5%3E3.0.CO%3B2-2","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11
Abstract
The redox indicator, ferroin, tris(1,10-phenanthroline)iron(II) was incorporated into the perfluorosulfonated cation-exchange membrane Nafion and, together with optical fibers, a photodiode, and a light-emitting diode, was used for the construction of a redox optical sensor (optode). The optode was incorporated in the flow-through cell of a computer-controlled sequential injection (SI) system and used for the determination of ascorbic acid (vitamin C). A linear relationship between the logarithm of the ascorbic acid concentration and the membrane absorbance was obtained for the concentration range from 2.50 × 10−3 to 1.00 × 10−1 mol L−1 and a sample frequency of 17 h−1. The concentration of ascorbic acid determined in a number of commercial pharmaceutical products agreed well with iodometric titration results. This result shows that the SI system incorporating the ferroin/Nafion optode is suitable for the automated analysis of ascorbic acid in pharmaceutical products. © 2000 John Wiley & Sons, Inc. Lab Robotics and Automation 12:200–204, 2000
一种测定抗坏血酸的光学膜氧化还原化学传感器
将氧化还原指示剂亚铁,三(1,10-菲罗啉)铁(II)掺入全氟磺化阳离子交换膜Nafion中,并与光纤、光电二极管和发光二极管一起用于构建氧化还原光学传感器(光电二极管)。在计算机控制的顺序注射(SI)系统的流动池中加入光电元件,用于测定抗坏血酸(维生素C)。在2.50 × 10−3 ~ 1.00 × 10−1 mol L−1的浓度范围内,样品频率为17 h−1,抗坏血酸浓度的对数与膜吸光度之间存在线性关系。在一些商业药品中测定的抗坏血酸浓度与碘量滴定法的结果一致。结果表明,该系统可用于药品中抗坏血酸的自动分析。©2000 John Wiley &儿子,Inc。实验室机器人与自动化(12):200 - 204,2000
本文章由计算机程序翻译,如有差异,请以英文原文为准。