{"title":"Computation and Experiments on the Beam Spread in the VP-SEM: Application to X-Ray Microanalysis","authors":"A. Kadoun, R. Belkorissat, C. Mathieu, B. Khelifa","doi":"10.1081/TMA-120020258","DOIUrl":null,"url":null,"abstract":"Abstract X-ray microanalysis (XRMA) coupled to a variable pressure scanning electron microscope (VP-SEM) using air atmosphere in the specimen chamber performed on test structures were used to make comparison with a Monte Carlo simulation program based on the modeling of the electron beam-gas interaction. The results show that the extent of the beam spreading can be significantly reduced at relatively high pressures by using helium gas instead of air and considerably reduced even at low pressure by lowering the analytical distance.","PeriodicalId":17525,"journal":{"name":"Journal of Trace and Microprobe Techniques","volume":"71 1","pages":"229 - 238"},"PeriodicalIF":0.0000,"publicationDate":"2003-01-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Trace and Microprobe Techniques","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1081/TMA-120020258","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

Abstract

Abstract X-ray microanalysis (XRMA) coupled to a variable pressure scanning electron microscope (VP-SEM) using air atmosphere in the specimen chamber performed on test structures were used to make comparison with a Monte Carlo simulation program based on the modeling of the electron beam-gas interaction. The results show that the extent of the beam spreading can be significantly reduced at relatively high pressures by using helium gas instead of air and considerably reduced even at low pressure by lowering the analytical distance.
VP-SEM中光束扩散的计算与实验:在x射线微分析中的应用
摘要:采用x射线微分析(XRMA)和变压扫描电镜(VP-SEM)结合试样室内空气环境对试验结构进行了分析,并与基于电子束-气体相互作用建模的蒙特卡罗模拟程序进行了比较。结果表明,在较高的压力下,用氦气代替空气可以显著减小光束的扩散范围;在较低的压力下,通过减小分析距离也可以显著减小光束的扩散范围。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信