Effects of transmission line tower grounding improvements on its lightning performance

L. Diaz, F. Grange, S. Journet, F. Dawalibi
{"title":"Effects of transmission line tower grounding improvements on its lightning performance","authors":"L. Diaz, F. Grange, S. Journet, F. Dawalibi","doi":"10.1109/ICLPandSIPDA54065.2021.9627425","DOIUrl":null,"url":null,"abstract":"Improvement of transmission line tower grounding is of particular importance for the line service quality. The tower transient impedance is a key parameter for the prediction and estimation of transmission line performance under abnormal conditions including lightning strikes. In this paper we compare the impulse impedance to the low frequency resistance of the tower by evaluating their respective effects on back-flashovers estimation. Based on real-case scenarios of grounding system configurations the critical current is computed and analysed to estimate the gain in the tower-footing grounding system design.","PeriodicalId":70714,"journal":{"name":"中国防雷","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"中国防雷","FirstCategoryId":"1089","ListUrlMain":"https://doi.org/10.1109/ICLPandSIPDA54065.2021.9627425","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Improvement of transmission line tower grounding is of particular importance for the line service quality. The tower transient impedance is a key parameter for the prediction and estimation of transmission line performance under abnormal conditions including lightning strikes. In this paper we compare the impulse impedance to the low frequency resistance of the tower by evaluating their respective effects on back-flashovers estimation. Based on real-case scenarios of grounding system configurations the critical current is computed and analysed to estimate the gain in the tower-footing grounding system design.
输电线路塔架接地改进对其防雷性能的影响
输电线路塔架接地的改善对线路的服务质量尤为重要。杆塔暂态阻抗是预测和估计包括雷击在内的异常情况下输电线路性能的关键参数。在本文中,我们比较了脉冲阻抗和低频电阻对反闪络估计的影响。根据接地系统配置的实际情况,计算和分析了接地系统设计中的临界电流,以估计接地系统的增益。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
57
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信