Differences in nickel ions released from nickel-titanium arch wire after immersion in detergent and non-detergent toothpaste

H. Lubis, K. Harahap, Nadia Tamari Lubis
{"title":"Differences in nickel ions released from nickel-titanium arch wire after immersion in detergent and non-detergent toothpaste","authors":"H. Lubis, K. Harahap, Nadia Tamari Lubis","doi":"10.22146/MAJKEDGIIND.41564","DOIUrl":null,"url":null,"abstract":"Nickel-titanium (NiTi) arch wire has properties that favor its use during the leveling and aligning phase of orthodontic treatment. This NiTi orthodontic arch wire has the potential to experience nickel ion release. One factor that can cause the release of nickel ions is toothpaste. Nickel ions released can enter the body and cause carcinogenic, mutagenic, cytotoxic, and allergic effects. The purpose of this study was to see the differences of nickel ions released from NiTi orthodontic arch wire after immersion in detergent and non-detergent toothpaste. This was a laboratory experimental research to draft a comparative design. The sample size was 40 pieces of NiTi orthodontic arch wire which were divided into 2 groups, immersion in detergent toothpaste and immersion in non-detergent toothpaste. The sample used was NiTi arch wire solution immersed in toothpaste and distilled water for 24 hours in an incubator at 37 °C then measured using inductively coupled plasma (ICP) mass spectrometer to determine the released nickel ions. Data were analyzed usingMann-Whitney test. The Mann-Whitney test resulted in a value of 0.872 (p≥0.05) which indicates no significant difference between the two groups. The study concluded that there is no difference in the nickel ions released from NiTi orthodonticarchwire after immersion in detergent and non-detergent toothpaste.","PeriodicalId":31262,"journal":{"name":"Majalah Kedokteran Gigi Indonesia","volume":"39 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-01-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Majalah Kedokteran Gigi Indonesia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22146/MAJKEDGIIND.41564","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Nickel-titanium (NiTi) arch wire has properties that favor its use during the leveling and aligning phase of orthodontic treatment. This NiTi orthodontic arch wire has the potential to experience nickel ion release. One factor that can cause the release of nickel ions is toothpaste. Nickel ions released can enter the body and cause carcinogenic, mutagenic, cytotoxic, and allergic effects. The purpose of this study was to see the differences of nickel ions released from NiTi orthodontic arch wire after immersion in detergent and non-detergent toothpaste. This was a laboratory experimental research to draft a comparative design. The sample size was 40 pieces of NiTi orthodontic arch wire which were divided into 2 groups, immersion in detergent toothpaste and immersion in non-detergent toothpaste. The sample used was NiTi arch wire solution immersed in toothpaste and distilled water for 24 hours in an incubator at 37 °C then measured using inductively coupled plasma (ICP) mass spectrometer to determine the released nickel ions. Data were analyzed usingMann-Whitney test. The Mann-Whitney test resulted in a value of 0.872 (p≥0.05) which indicates no significant difference between the two groups. The study concluded that there is no difference in the nickel ions released from NiTi orthodonticarchwire after immersion in detergent and non-detergent toothpaste.
镍钛拱丝浸泡在洗洁精和非洗洁精牙膏中镍离子释放的差异
镍钛(NiTi)弓丝在正畸治疗的调平和对准阶段具有良好的使用性能。这种镍钛正畸弓丝有可能经历镍离子释放。导致镍离子释放的一个因素是牙膏。释放出的镍离子可进入人体并引起致癌、致突变、细胞毒性和过敏作用。本研究的目的是观察NiTi正畸弓丝浸泡在洗洁精和非洗洁精牙膏中释放的镍离子的差异。这是一项实验室实验研究起草的比较设计。样本量为40根NiTi正畸弓丝,分为浸泡在含洗洁精牙膏和浸泡在无洗洁精牙膏两组。样品为NiTi弓丝溶液,在37℃的培养箱中,用牙膏和蒸馏水浸泡24小时,然后用电感耦合等离子体(ICP)质谱仪测定镍离子释放量。数据分析采用mann - whitney检验。Mann-Whitney检验结果为0.872 (p≥0.05),两组间差异无统计学意义。本研究得出结论:NiTi正畸丝在洗洁精和非洗洁精牙膏中浸泡后释放的镍离子没有差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
审稿时长
20 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信