Failure Modes of Sheet Bonded Fiber Reinforced Polymer Applied to Brick Masonry

玻璃钢 Pub Date : 1999-08-01 DOI:10.14359/5632
K. Roko, T. Boothby, C. Bakis
{"title":"Failure Modes of Sheet Bonded Fiber Reinforced Polymer Applied to Brick Masonry","authors":"K. Roko, T. Boothby, C. Bakis","doi":"10.14359/5632","DOIUrl":null,"url":null,"abstract":"CFRP reinforcement sheets are proposed as reinforcement for unreinforced brick masonry subjected to out of plane loads. The investigation consisted of testing unidirectional sheet bonded carbon fiber as a reinforcing material for brick masonry prisms. Two types of brick and FRP materials were utilized in these experiments. The masonry materials exhibited high and low porosity, indicated by initial rate of absorption tests, while high and low modulus FRP materials were used. Strain gauge and full field photoelastic strain analysis was conducted to obtain a record of the strain transfer from the FRP to the masonry. From this analysis, a finite element model was then constructed to predict the mode and magnitude of failure. Results indicate that shear failure of the brick or debonding of the FRP were the general failure modes of the composite specimens tested. When comparing the results of different brick types, it is seen that, in the molded brick, the failure mode was shear failure of the brick at the end of the FRP reinforcement. In these specimens, it is clearly seen in the photoelastic strain results that strain transfer in the brick occurred in an area adjacent to the FRP. Failure in the extruded brick specimens was governed by the debonding of the FRP at the interface with the prism. It is conjectured that the viscosity of the epoxy and the porosity of the brick, characterized by initial rate of absorption tests, directly affect the bond of the composite structure and, therefore, the failure mode. Photoelastic results reveal that strain transfer does occur at high loads when the FRP remains bonded to the masonry. A linearly elastic finite element model was generated to match the experimental results and predict the failure mode for future design purposes. This model can be used for various configurations of FRP in the future.","PeriodicalId":68258,"journal":{"name":"玻璃钢","volume":"101 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"1999-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"玻璃钢","FirstCategoryId":"1087","ListUrlMain":"https://doi.org/10.14359/5632","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17

Abstract

CFRP reinforcement sheets are proposed as reinforcement for unreinforced brick masonry subjected to out of plane loads. The investigation consisted of testing unidirectional sheet bonded carbon fiber as a reinforcing material for brick masonry prisms. Two types of brick and FRP materials were utilized in these experiments. The masonry materials exhibited high and low porosity, indicated by initial rate of absorption tests, while high and low modulus FRP materials were used. Strain gauge and full field photoelastic strain analysis was conducted to obtain a record of the strain transfer from the FRP to the masonry. From this analysis, a finite element model was then constructed to predict the mode and magnitude of failure. Results indicate that shear failure of the brick or debonding of the FRP were the general failure modes of the composite specimens tested. When comparing the results of different brick types, it is seen that, in the molded brick, the failure mode was shear failure of the brick at the end of the FRP reinforcement. In these specimens, it is clearly seen in the photoelastic strain results that strain transfer in the brick occurred in an area adjacent to the FRP. Failure in the extruded brick specimens was governed by the debonding of the FRP at the interface with the prism. It is conjectured that the viscosity of the epoxy and the porosity of the brick, characterized by initial rate of absorption tests, directly affect the bond of the composite structure and, therefore, the failure mode. Photoelastic results reveal that strain transfer does occur at high loads when the FRP remains bonded to the masonry. A linearly elastic finite element model was generated to match the experimental results and predict the failure mode for future design purposes. This model can be used for various configurations of FRP in the future.
薄板粘结纤维增强聚合物在砖砌体中的破坏模式
提出了CFRP配筋板作为面外荷载作用下无筋砖砌体的配筋。本研究主要是测试碳纤维单向板作为砖砌体棱镜的增强材料。实验采用砖和FRP两种材料。砌体材料在初始吸收率试验中表现为高孔隙率和低孔隙率,而采用高模量和低模量FRP材料。进行了应变计和全场光弹应变分析,以获得从FRP到砌体的应变传递记录。在此基础上,建立了有限元模型来预测破坏模式和破坏程度。结果表明,砌块的剪切破坏或FRP的脱粘是复合材料试件的常见破坏模式。对比不同砖型的结果可以看出,在模制砖中,FRP加固末端砖的破坏模式为剪切破坏。在这些试样中,在光弹性应变结果中可以清楚地看到,砖中的应变传递发生在与FRP相邻的区域。挤压砖试件的破坏是由玻璃钢与棱柱界面处的脱粘控制的。据推测,环氧树脂的粘度和砖的孔隙率(以初始吸收速率为特征)直接影响复合材料结构的粘结,从而影响其破坏模式。光弹性结果表明,应变传递确实发生在高荷载时,FRP保持粘结砌体。建立了线弹性有限元模型,与试验结果相匹配,并为今后的设计预测了失效模式。该模型可用于未来FRP的各种配置。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
357
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书