Power factor correction circuit with one cycle controlled bridgeless zeta converter for display monitors in hospitals

Preethy V. Warrier, P. Preetha
{"title":"Power factor correction circuit with one cycle controlled bridgeless zeta converter for display monitors in hospitals","authors":"Preethy V. Warrier, P. Preetha","doi":"10.1109/TENCON.2015.7372886","DOIUrl":null,"url":null,"abstract":"Development in the field of electrical engineering is quick and commendable. Even though the nonlinear power electronic equipments introduce power quality issues, their use is unavoidable. Most of the medical equipments make use of power electronic devices. Serious issues include low input power factor and increased ripples in the input current. Many bridgeless topologies have been introduced to mitigate the above mentioned problems. Common topologies make use of buck, boost, Cuk and Sepic converters. In this paper bridgeless zeta converter with one cycle control for display monitors in hospitals has been proposed. With one cycle control, input perturbations are avoided in one switching cycle. The converter is designed to supply the load of 50W and 24V. MATLAB/Simulink model has been analyzed for various conditions. A laboratory prototype of the converter has also been made and tested for the designed values. Results of simulation have been verified with the hardware system. Power factor has been observed to be above 0.97.","PeriodicalId":22200,"journal":{"name":"TENCON 2015 - 2015 IEEE Region 10 Conference","volume":"50 1","pages":"1-6"},"PeriodicalIF":0.0000,"publicationDate":"2015-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"TENCON 2015 - 2015 IEEE Region 10 Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TENCON.2015.7372886","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

Abstract

Development in the field of electrical engineering is quick and commendable. Even though the nonlinear power electronic equipments introduce power quality issues, their use is unavoidable. Most of the medical equipments make use of power electronic devices. Serious issues include low input power factor and increased ripples in the input current. Many bridgeless topologies have been introduced to mitigate the above mentioned problems. Common topologies make use of buck, boost, Cuk and Sepic converters. In this paper bridgeless zeta converter with one cycle control for display monitors in hospitals has been proposed. With one cycle control, input perturbations are avoided in one switching cycle. The converter is designed to supply the load of 50W and 24V. MATLAB/Simulink model has been analyzed for various conditions. A laboratory prototype of the converter has also been made and tested for the designed values. Results of simulation have been verified with the hardware system. Power factor has been observed to be above 0.97.
医院显示器用一周期可控无桥zeta变换器功率因数校正电路
电气工程领域的发展是迅速而值得赞扬的。尽管非线性电力电子设备存在电能质量问题,但其使用是不可避免的。大多数医疗设备都使用电力电子设备。严重的问题包括输入功率因数低和输入电流波动增加。已经引入了许多无桥拓扑来缓解上述问题。常见的拓扑使用降压、升压、Cuk和Sepic转换器。本文提出了一种用于医院显示器的无桥单周期控制zeta变换器。采用单周期控制,可以在一个切换周期内避免输入扰动。该变换器设计用于提供50W和24V的负载。对MATLAB/Simulink模型进行了各种工况分析。还制作了转换器的实验室样机,并对设计值进行了测试。仿真结果在硬件系统上得到了验证。功率因数已被观察到高于0.97。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信