An Anomaly Detection Algorithm of Satellite Power System Based on CUSUM Control Chart

Li Yuqing, Yang Tianshe, Chen Xueliang, Wang Rixin, Xu Minqiang
{"title":"An Anomaly Detection Algorithm of Satellite Power System Based on CUSUM Control Chart","authors":"Li Yuqing, Yang Tianshe, Chen Xueliang, Wang Rixin, Xu Minqiang","doi":"10.1109/ICISCE.2016.181","DOIUrl":null,"url":null,"abstract":"According to the characteristics of the power supply subsystem, this paper proposes a CUSUM control chart approach to tackle the anomaly detection and fault early warning for the satellite power supply subsystem. Firstly, through the comparison and analysis about satellites remote sensing data, this paper selects power hydrogen pressure value as a characteristic. Secondly, this paper establishes the CUSUM control chart of the power hydrogen pressure, and then detects anomaly in the satellite power system using this CUSUM control chart. Analysis of satellite telemetry data shows that when the satellite state is abnormal, the value of the characteristic will be changed and this can be recognized by the method presented in this paper, as well as the fault early warning will be given. That achieves the purposes on the satellite power system anomaly detection and fault early warning.","PeriodicalId":6882,"journal":{"name":"2016 3rd International Conference on Information Science and Control Engineering (ICISCE)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2016-07-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 3rd International Conference on Information Science and Control Engineering (ICISCE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICISCE.2016.181","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

According to the characteristics of the power supply subsystem, this paper proposes a CUSUM control chart approach to tackle the anomaly detection and fault early warning for the satellite power supply subsystem. Firstly, through the comparison and analysis about satellites remote sensing data, this paper selects power hydrogen pressure value as a characteristic. Secondly, this paper establishes the CUSUM control chart of the power hydrogen pressure, and then detects anomaly in the satellite power system using this CUSUM control chart. Analysis of satellite telemetry data shows that when the satellite state is abnormal, the value of the characteristic will be changed and this can be recognized by the method presented in this paper, as well as the fault early warning will be given. That achieves the purposes on the satellite power system anomaly detection and fault early warning.
基于CUSUM控制图的卫星电力系统异常检测算法
针对卫星供电子系统的特点,提出了一种CUSUM控制图方法来解决卫星供电子系统的异常检测和故障预警问题。首先,通过对卫星遥感数据的对比分析,选择动力氢气压力值作为特征。其次,建立了电力氢气压力CUSUM控制图,并利用CUSUM控制图检测卫星电力系统异常。对卫星遥测数据的分析表明,当卫星状态异常时,特征值会发生变化,本文提出的方法可以识别出卫星状态异常,并给出故障预警。从而达到了卫星电力系统异常检测和故障预警的目的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信