{"title":"Effect of traction substation for high speed railway in Indonesia","authors":"A. A. Kusuma, B. S. Munir, P. Pramana","doi":"10.1109/ICECOS.2017.8167153","DOIUrl":null,"url":null,"abstract":"This paper discuss about effect of traction substation for high speed railway in Indonesia. The purpose of this paper is to obtain magnitude of voltage and current unbalance due to traction substation that perceived by system and generator adjacent to traction substation. Analysis is performed by doing simulation of 5 scenarios in simple system model that created in power system simulation program. These 5 scenarios are being performed to represent the actual condition of Indonesia power system. Based on the analysis of simulation result, it can be stated that the magnitude of voltage and current unbalance on system and generator are influenced by magnitude of system short circuit level (SCL), position of supply substation to traction location, amount number of power plant near to traction location, percentage impedance of generator transformer, and the magnitude of generator load.","PeriodicalId":6528,"journal":{"name":"2017 International Conference on Electrical Engineering and Computer Science (ICECOS)","volume":"30 1","pages":"295-299"},"PeriodicalIF":0.0000,"publicationDate":"2017-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 International Conference on Electrical Engineering and Computer Science (ICECOS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICECOS.2017.8167153","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

This paper discuss about effect of traction substation for high speed railway in Indonesia. The purpose of this paper is to obtain magnitude of voltage and current unbalance due to traction substation that perceived by system and generator adjacent to traction substation. Analysis is performed by doing simulation of 5 scenarios in simple system model that created in power system simulation program. These 5 scenarios are being performed to represent the actual condition of Indonesia power system. Based on the analysis of simulation result, it can be stated that the magnitude of voltage and current unbalance on system and generator are influenced by magnitude of system short circuit level (SCL), position of supply substation to traction location, amount number of power plant near to traction location, percentage impedance of generator transformer, and the magnitude of generator load.
印尼高速铁路牵引变电所的效果
本文探讨了印尼高速铁路牵引变电所的作用。本文的目的是获得牵引变电所引起的电压、电流不平衡的大小,由牵引变电所附近的系统和发电机感知。通过在电力系统仿真程序中建立简单的系统模型,对5种场景进行仿真分析。这5个场景是为了代表印尼电力系统的实际情况而进行的。通过对仿真结果的分析可知,系统短路电平(SCL)的大小、供电变电所对牵引位置的位置、牵引位置附近电厂的数量、发电机变压器的百分比阻抗以及发电机负载的大小都对系统和发电机的电压和电流不平衡的大小有影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信