Quantification of Dimethylacetamide and its Primary Metabolite Monomethylacetamide in Plasma Using Robust LC-MS Method

Fadwa Benkessou, Ibrahim El Serafi, Brigitte Twelkmeyer, M. Abedi‐Valugerdi, Moustapha Hassan
{"title":"Quantification of Dimethylacetamide and its Primary Metabolite Monomethylacetamide in Plasma Using Robust LC-MS Method","authors":"Fadwa Benkessou, Ibrahim El Serafi, Brigitte Twelkmeyer, M. Abedi‐Valugerdi, Moustapha Hassan","doi":"10.4172/2155-9872.1000327","DOIUrl":null,"url":null,"abstract":"N,N-Dimethylacetamide (DMA) is an excellent solvent that is highly used in the production of synthetic fibres as well as in the pharmaceutical industry. It is present as a solvent in the intravenous formulation of busulphan, a drug used in high doses as myeloablative treatment prior to hematopoietic stem cell transplantation (SCT). DMA was shown to cause hepatotoxicity as well as neurotoxicity, as revealed throughout several studies including phase I study. In the present investigation we developed an LC-MS based method to detect and quantify DMA and its primary metabolite N-monomethylacetamide (MMA) simultaneously in human plasma, using a C-18 ODS-AQ/S-5 µm 12 nm separation column. The lower limits of quantification (LLOQs) for DMA and MMA were 1.8 µM and 8.6 µM, respectively. The limit of detection (LOD) for DMA and MMA were 0.53 µM and 2.52 µM, respectively. The recovery of DMA from plasma ranged from 97-101% and for MMA from 76-100%. The stability for DMA and MMA was assessed through freeze-thaw cycles and storage at different temperatures (RT, 4°C and -20°C for three days); the results have shown <7.9% CV for DMA and <14.1% for MMA. The inter-day and intra-day variation assay accuracy and precision was <6.3% for DMA and <8.6% for MMA. The calibration was linear within the ranges 1 to 4000 µM. The method was applied to follow the kinetics and to quantify DMA and its metabolite MMA in 49 plasma samples from 2 patients undergoing SCT and treated with intravenous busulphan that contain DMA. The present method is simple, robust and showed good selectivity with high accuracy, precision and reproducibility. Moreover, it can be utilized to determine DMA and its metabolite in workers, patients and environment and hence avoid toxic exposure.","PeriodicalId":14865,"journal":{"name":"Journal of analytical and bioanalytical techniques","volume":"30 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2016-07-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of analytical and bioanalytical techniques","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4172/2155-9872.1000327","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

N,N-Dimethylacetamide (DMA) is an excellent solvent that is highly used in the production of synthetic fibres as well as in the pharmaceutical industry. It is present as a solvent in the intravenous formulation of busulphan, a drug used in high doses as myeloablative treatment prior to hematopoietic stem cell transplantation (SCT). DMA was shown to cause hepatotoxicity as well as neurotoxicity, as revealed throughout several studies including phase I study. In the present investigation we developed an LC-MS based method to detect and quantify DMA and its primary metabolite N-monomethylacetamide (MMA) simultaneously in human plasma, using a C-18 ODS-AQ/S-5 µm 12 nm separation column. The lower limits of quantification (LLOQs) for DMA and MMA were 1.8 µM and 8.6 µM, respectively. The limit of detection (LOD) for DMA and MMA were 0.53 µM and 2.52 µM, respectively. The recovery of DMA from plasma ranged from 97-101% and for MMA from 76-100%. The stability for DMA and MMA was assessed through freeze-thaw cycles and storage at different temperatures (RT, 4°C and -20°C for three days); the results have shown <7.9% CV for DMA and <14.1% for MMA. The inter-day and intra-day variation assay accuracy and precision was <6.3% for DMA and <8.6% for MMA. The calibration was linear within the ranges 1 to 4000 µM. The method was applied to follow the kinetics and to quantify DMA and its metabolite MMA in 49 plasma samples from 2 patients undergoing SCT and treated with intravenous busulphan that contain DMA. The present method is simple, robust and showed good selectivity with high accuracy, precision and reproducibility. Moreover, it can be utilized to determine DMA and its metabolite in workers, patients and environment and hence avoid toxic exposure.
高效液相色谱-质谱法定量血浆中二甲基乙酰胺及其初级代谢物单甲基乙酰胺
N,N-二甲基乙酰胺(DMA)是一种优良的溶剂,广泛用于合成纤维的生产以及制药工业。它作为一种溶剂存在于布硫芬静脉制剂中,布硫芬是一种用于造血干细胞移植(SCT)前的高剂量清髓治疗药物。包括I期研究在内的几项研究显示,DMA可引起肝毒性和神经毒性。本研究建立了一种基于LC-MS的方法,采用C-18 ODS-AQ/S-5µm 12 nm分离柱,同时检测和定量人血浆中DMA及其主要代谢物n -单甲基乙酰胺(MMA)。DMA和MMA的定量下限(lloq)分别为1.8µM和8.6µM。DMA和MMA的检出限分别为0.53µM和2.52µM。血浆中DMA回收率为97-101%,MMA回收率为76-100%。通过冻融循环和不同温度(RT、4°C和-20°C)保存3天,评估DMA和MMA的稳定性;结果显示,DMA CV <7.9%, MMA CV <14.1%。日间和日间变化测定的准确度和精密度DMA <6.3%, MMA <8.6%。校准在1 ~ 4000µM范围内呈线性。该方法用于跟踪2例接受SCT并静脉注射含有DMA的布硫芬治疗的患者的49份血浆样本的动力学并量化DMA及其代谢物MMA。该方法简便、鲁棒性好,选择性好,准确度、精密度高,重现性好。此外,它还可以用来测定工人、患者和环境中的DMA及其代谢物,从而避免有毒暴露。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信