Air Quality in Fitness Centers

Q4 Engineering
Cátia Peixoto, K. Slezakova, M. C. Pereira, Simone Morais
{"title":"Air Quality in Fitness Centers","authors":"Cátia Peixoto, K. Slezakova, M. C. Pereira, Simone Morais","doi":"10.24840/2183-6493_008.004_0004","DOIUrl":null,"url":null,"abstract":"To stay healthy, people frequent sports facilities. This work aimed to evaluate air pollution and comfort parameters in a fitness club in the post lockdown period (due to the COVID-19 pandemic), focusing on particulate material (PM10, PM2.5) and gaseous pollutants (total volatile organic compounds -TVOCs, carbon dioxide - CO2, and carbon monoxide – CO). Sampling was carried out for 10 consecutive days in October 2020 in one fitness center (Oporto, Portugal). The results showed that indoor PM10 ranged from 1.4 to 122.5 µg/m3 and PM2.5 was between 0.8 and 25 µg/m3; the overall levels were in accordance with the current legislation. TVOC means were 0.39 mg/m3 when not occupied and 0.43 mg/m3 when exercising subjects were present, thus also fulfilling the limit 0.6 mg/m3). Average CO2 was 1400 mg/m3 with temporal maxima (2660-2894 mg/m3) exceeding the protection threshold. Finally, temperature and relative humidity exceeded the recommended comfort levels, especially during group activity classes.","PeriodicalId":36339,"journal":{"name":"U.Porto Journal of Engineering","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-07-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"U.Porto Journal of Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24840/2183-6493_008.004_0004","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 1

Abstract

To stay healthy, people frequent sports facilities. This work aimed to evaluate air pollution and comfort parameters in a fitness club in the post lockdown period (due to the COVID-19 pandemic), focusing on particulate material (PM10, PM2.5) and gaseous pollutants (total volatile organic compounds -TVOCs, carbon dioxide - CO2, and carbon monoxide – CO). Sampling was carried out for 10 consecutive days in October 2020 in one fitness center (Oporto, Portugal). The results showed that indoor PM10 ranged from 1.4 to 122.5 µg/m3 and PM2.5 was between 0.8 and 25 µg/m3; the overall levels were in accordance with the current legislation. TVOC means were 0.39 mg/m3 when not occupied and 0.43 mg/m3 when exercising subjects were present, thus also fulfilling the limit 0.6 mg/m3). Average CO2 was 1400 mg/m3 with temporal maxima (2660-2894 mg/m3) exceeding the protection threshold. Finally, temperature and relative humidity exceeded the recommended comfort levels, especially during group activity classes.
健身中心的空气质量
为了保持健康,人们经常去体育设施。本研究旨在评估健身俱乐部在封锁后(由于COVID-19大流行)的空气污染和舒适参数,重点关注颗粒物(PM10, PM2.5)和气态污染物(总挥发性有机化合物- tvocs,二氧化碳- CO2和一氧化碳- CO)。2020年10月,在一个健身中心(葡萄牙波尔图)连续10天进行抽样。结果表明:室内PM10在1.4 ~ 122.5µg/m3之间,PM2.5在0.8 ~ 25µg/m3之间;总体水平符合现行立法。TVOC均值在不占用时为0.39 mg/m3,在运动对象在场时为0.43 mg/m3,也达到0.6 mg/m3的限值)。平均CO2为1400 mg/m3,时间最大值(2660 ~ 2894 mg/m3)超过保护阈值。最后,温度和相对湿度超过了推荐的舒适水平,特别是在团体活动课程期间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
U.Porto Journal of Engineering
U.Porto Journal of Engineering Engineering-Engineering (all)
CiteScore
0.70
自引率
0.00%
发文量
58
审稿时长
20 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信