Cátia Peixoto, K. Slezakova, M. C. Pereira, Simone Morais
{"title":"Air Quality in Fitness Centers","authors":"Cátia Peixoto, K. Slezakova, M. C. Pereira, Simone Morais","doi":"10.24840/2183-6493_008.004_0004","DOIUrl":null,"url":null,"abstract":"To stay healthy, people frequent sports facilities. This work aimed to evaluate air pollution and comfort parameters in a fitness club in the post lockdown period (due to the COVID-19 pandemic), focusing on particulate material (PM10, PM2.5) and gaseous pollutants (total volatile organic compounds -TVOCs, carbon dioxide - CO2, and carbon monoxide – CO). Sampling was carried out for 10 consecutive days in October 2020 in one fitness center (Oporto, Portugal). The results showed that indoor PM10 ranged from 1.4 to 122.5 µg/m3 and PM2.5 was between 0.8 and 25 µg/m3; the overall levels were in accordance with the current legislation. TVOC means were 0.39 mg/m3 when not occupied and 0.43 mg/m3 when exercising subjects were present, thus also fulfilling the limit 0.6 mg/m3). Average CO2 was 1400 mg/m3 with temporal maxima (2660-2894 mg/m3) exceeding the protection threshold. Finally, temperature and relative humidity exceeded the recommended comfort levels, especially during group activity classes.","PeriodicalId":36339,"journal":{"name":"U.Porto Journal of Engineering","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-07-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"U.Porto Journal of Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24840/2183-6493_008.004_0004","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 1
Abstract
To stay healthy, people frequent sports facilities. This work aimed to evaluate air pollution and comfort parameters in a fitness club in the post lockdown period (due to the COVID-19 pandemic), focusing on particulate material (PM10, PM2.5) and gaseous pollutants (total volatile organic compounds -TVOCs, carbon dioxide - CO2, and carbon monoxide – CO). Sampling was carried out for 10 consecutive days in October 2020 in one fitness center (Oporto, Portugal). The results showed that indoor PM10 ranged from 1.4 to 122.5 µg/m3 and PM2.5 was between 0.8 and 25 µg/m3; the overall levels were in accordance with the current legislation. TVOC means were 0.39 mg/m3 when not occupied and 0.43 mg/m3 when exercising subjects were present, thus also fulfilling the limit 0.6 mg/m3). Average CO2 was 1400 mg/m3 with temporal maxima (2660-2894 mg/m3) exceeding the protection threshold. Finally, temperature and relative humidity exceeded the recommended comfort levels, especially during group activity classes.