Effect of Aluminum Chloride Hemostatic Agent on Bonding Strength of RMGIC in Primary Tooth

S. Woo, Jisun Shin, Joonhaeng Lee, Miran Han, Jong Soo Kim
{"title":"Effect of Aluminum Chloride Hemostatic Agent on Bonding Strength of RMGIC in Primary Tooth","authors":"S. Woo, Jisun Shin, Joonhaeng Lee, Miran Han, Jong Soo Kim","doi":"10.5933/jkapd.2021.48.4.397","DOIUrl":null,"url":null,"abstract":"The purpose of this study was to evaluate the effect of a hemostatic agent containing aluminum chloride on the shear bond strength of resin-modified glass ionomer cement (RMGIC) to the dentin of primary teeth. Thirty-six extracted non-carious human primary teeth were collected in this study. Dentin surfaces were cut and polished. The specimens were randomly divided into 4 groups; group I: RMGIC without conditioning; group II: polyacrylic acid (PAA), RMGIC; group III: aluminum chloride, RMGIC; group IV: aluminum chloride, PAA, RMGIC. All teeth were thermocycled between 5.0℃ and 55.0℃ for 5000 cycles. Fifteen specimens from each group were subjected to shear bond strength test and 3 specimens from each group were inspected using scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy. The mean shear bond strength of each group was as follows: 4.04 ± 0.88 MPa in group I, 8.29 ± 1.40 MPa in group II, 1.39 ± 0.47 MPa in group III, 6.24 ± 2.76 MPa in group IV. There were significant differences among all groups (p < 0.001). SEM image of the dentinal tubules were partially exposed in group III and group IV. Fully exposed dentinal tubules were found in group II. In conclusion, aluminum chloride decreased the shear bond strength of RMGIC to dentin, regardless of PAA conditioning.","PeriodicalId":22818,"journal":{"name":"THE JOURNAL OF THE KOREAN ACADEMY OF PEDTATRIC DENTISTRY","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"THE JOURNAL OF THE KOREAN ACADEMY OF PEDTATRIC DENTISTRY","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5933/jkapd.2021.48.4.397","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The purpose of this study was to evaluate the effect of a hemostatic agent containing aluminum chloride on the shear bond strength of resin-modified glass ionomer cement (RMGIC) to the dentin of primary teeth. Thirty-six extracted non-carious human primary teeth were collected in this study. Dentin surfaces were cut and polished. The specimens were randomly divided into 4 groups; group I: RMGIC without conditioning; group II: polyacrylic acid (PAA), RMGIC; group III: aluminum chloride, RMGIC; group IV: aluminum chloride, PAA, RMGIC. All teeth were thermocycled between 5.0℃ and 55.0℃ for 5000 cycles. Fifteen specimens from each group were subjected to shear bond strength test and 3 specimens from each group were inspected using scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy. The mean shear bond strength of each group was as follows: 4.04 ± 0.88 MPa in group I, 8.29 ± 1.40 MPa in group II, 1.39 ± 0.47 MPa in group III, 6.24 ± 2.76 MPa in group IV. There were significant differences among all groups (p < 0.001). SEM image of the dentinal tubules were partially exposed in group III and group IV. Fully exposed dentinal tubules were found in group II. In conclusion, aluminum chloride decreased the shear bond strength of RMGIC to dentin, regardless of PAA conditioning.
氯化铝止血剂对乳牙RMGIC粘接强度的影响
本研究旨在探讨含氯化铝的止血剂对树脂改性玻璃离子水门合剂(RMGIC)与乳牙牙本质剪切结合强度的影响。本研究收集了36颗拔除的无龋人乳牙。牙本质表面被切割和抛光。将标本随机分为4组;第一组:不加调理的RMGIC;第二组:聚丙烯酸(PAA), RMGIC;第三类:氯化铝,RMGIC;第四组:氯化铝、PAA、RMGIC。所有牙齿在5.0 ~ 55.0℃范围内热循环5000次。每组取15个试件进行剪切粘结强度试验,每组取3个试件进行扫描电镜(SEM)和x射线能谱分析。各组平均剪切结合强度分别为:ⅰ组4.04±0.88 MPa、ⅱ组8.29±1.40 MPa、ⅲ组1.39±0.47 MPa、ⅳ组6.24±2.76 MPa,各组间差异有统计学意义(p < 0.001)。III组和IV组牙本质小管部分暴露,II组牙本质小管完全暴露。综上所述,与PAA条件无关,氯化铝降低了RMGIC与牙本质的剪切结合强度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信