Investigation of the Breakdown Voltage of Insulation Oils at Medium Frequency after Thermal Ageing

J. Vocke, R. Möller, R. Puffer, B. Soppe
{"title":"Investigation of the Breakdown Voltage of Insulation Oils at Medium Frequency after Thermal Ageing","authors":"J. Vocke, R. Möller, R. Puffer, B. Soppe","doi":"10.1109/ICD46958.2020.9341873","DOIUrl":null,"url":null,"abstract":"Insulating oils and medium-frequency high voltages come together primarily where power electronic components are used, such as in power electronic transformers. For reliable long-term use, the insulation behaviour and, in particular, the breakdown voltage of the insulating oils at medium-frequency voltages is relevant, especially under consideration of ageing. Therefore, this paper investigates the influence of thermal ageing on the dielectric strength of insulating oil at medium frequency with an accelerated ageing test. Three insulating oils are each stored together with copper plates and insulating paper at 120 °C with controlled addition of air for an accelerated ageing. An oil sample is taken at fixed intervals and the breakdown voltage is determined for 2.2 kHz, 5.3 kHz and 8.6 kHz. In addition, the dielectric properties, acid number, water content and viscosity of each sample are determined. The investigations show a clear ageing dependency only for the acid number and the loss factor, all other parameters examined do not show such trend.","PeriodicalId":6795,"journal":{"name":"2020 IEEE 3rd International Conference on Dielectrics (ICD)","volume":"18 1","pages":"716-719"},"PeriodicalIF":0.0000,"publicationDate":"2020-07-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE 3rd International Conference on Dielectrics (ICD)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICD46958.2020.9341873","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Insulating oils and medium-frequency high voltages come together primarily where power electronic components are used, such as in power electronic transformers. For reliable long-term use, the insulation behaviour and, in particular, the breakdown voltage of the insulating oils at medium-frequency voltages is relevant, especially under consideration of ageing. Therefore, this paper investigates the influence of thermal ageing on the dielectric strength of insulating oil at medium frequency with an accelerated ageing test. Three insulating oils are each stored together with copper plates and insulating paper at 120 °C with controlled addition of air for an accelerated ageing. An oil sample is taken at fixed intervals and the breakdown voltage is determined for 2.2 kHz, 5.3 kHz and 8.6 kHz. In addition, the dielectric properties, acid number, water content and viscosity of each sample are determined. The investigations show a clear ageing dependency only for the acid number and the loss factor, all other parameters examined do not show such trend.
绝缘油热老化中频击穿电压的研究
绝缘油和中频高压主要在使用电力电子元件的地方结合在一起,例如电力电子变压器。为了可靠的长期使用,绝缘性能,特别是绝缘油在中频电压下的击穿电压是相关的,特别是在考虑到老化的情况下。为此,本文采用加速老化试验研究了热老化对绝缘油中频介电强度的影响。三种绝缘油分别与铜板和绝缘纸一起储存在120°C下,控制空气的添加以加速老化。以固定的间隔取样,并确定击穿电压为2.2 kHz、5.3 kHz和8.6 kHz。此外,还测定了各样品的介电性能、酸值、含水量和粘度。研究表明,只有酸值和损失因子具有明显的老化依赖性,所有其他参数均未显示出这种趋势。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信